5905-00-076-3454

RESISTOR,FIXED,WIRE WOUND


5905-00-076-3454 (5905000763454, 000763454)
Part Number (1 listing): RH50
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

5905-00-553-8197

Replacement Date: 31 Mar 1975

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-076-3454 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RH503 - Design Control Reference1 - Incomplete Part NumberVISHAY DALE ELECTRONICS, INC.  91637    CAGE 91637  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-076-3454 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905000763454A001A000010X1ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

000763454

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-076-3454

A001A0

Federal Item Identification Guide (FIIG_4065)

00010

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-076-3454 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
ZA011 Apr 1991
ZH011 Apr 1991
ZF011 Feb 2002
ZE011 Jun 2002
ZU011 Mar 2008
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-076-3454 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX0BTX031 Mar 1975 5905005538197 31 Mar 1975
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

31 Mar 1975

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-553-8197

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

31 Mar 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-076-3454 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-076-3454 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPPElectrical Resistance15.000 KILOHMS
AAQFAmbient Temp In Deg Celsius At Full Rated Power75.0
AAQGAmbient Temp In Deg Celsius At Zero Percent Rated Power275.0
ADAUBody Height0.625 INCHES NOMINAL
ADAQBody Length1.969 INCHES NOMINAL
ADATBody Width0.625 INCHES NOMINAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length1.562 INCHES NOMINAL
AAQAHeat Sink Length12.000 INCHES
AAPZHeat Sink MaterialALUMINUM ALLOY
AAQBHeat Sink Width12.000 INCHES
AAQEHeat Sink Thickness0.059 INCHES
BYMLMounting Hole Size0.125 INCHES NOMINAL
AAQZInclosure MethodENCAPSULATED
AEFBPower Dissipation Rating In Watts50.000 HEAT SINK
AAREReactance CharacteristicINDUCTIVE
AARGReliability IndicatorNOT ESTABLISHED
AAPQResistance Tolerance In Percent-5.000/+5.000
STYLStyle DesignatorAXIAL TERMINAL (S)
ABJTTerminal Length0.406 INCHES NOMINAL
AARBTerminal TypeTAB, SOLDER LUG


Back to Top