Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
C4-150G | 3 - Design Control Reference | 9 - No Longer Used | AVX CORP | 16299 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 000804883 | A001A0 | 05311 | X | 4 | 6 | A | N | A | A | 10 May 2002 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG01 | 1 May 2002 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 9 | 4 | 9Z | B | 1 | C4-150G | 16299 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 10 May 2002 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9Z | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
DLIS-K, Battle Creek, MI 49037-3084
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 15.000 OHMS |
AAQF | Ambient Temp In Deg Celsius At Full Rated Power | 21.110 |
AAQG | Ambient Temp In Deg Celsius At Zero Percent Rated Power | 150.0 |
AAQZ | Inclosure Method | ENCASED |
AEFB | Power Dissipation Rating In Watts | 0.250 FREE AIR |
AARG | Reliability Indicator | NOT ESTABLISHED |
AAPQ | Resistance Tolerance In Percent | -2.000/+2.000 |
STYL | Style Designator | AXIAL TERMINAL EACH END |
AAQH | Temp Range Of Temp Coefficient In Deg Celsius | -55.0 TO 175.0 |
AAPE | Temp Coefficient Of Resistance In Ppm Per Deg Celsius | -100.0/+100.0 |
AARB | Terminal Type | WIRE LEAD |