5905-00-103-1559

RESISTOR,VARIABLE,WIRE WOUND,NONPRECISION


5905-00-103-1559 (5905001031559, 001031559)
Part Numbers (3 listings): 54529-1 | RH0012H0500JDM | 265447-1 |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 14 Jun 1968

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.003 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-103-1559 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
54529-13 - Design Control Reference2 - Production ItemHEICO OHMITE, L.L.C.  44655    CAGE 44655  
RH0012H0500 JDM5 - Replaced / Discontinued2 - Production ItemMEMCOR INC  24681      
265447-15 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  49956    CAGE 49956  
265447-17 - Vendor Item Drawing Reference2 - Production ItemRAYTHEON TECHNICAL SERVICES COMPANY  3B150    CAGE 3B150  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-103-1559 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905001031559A002A037406X1ANU14 Jun 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

001031559

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-103-1559

A002A0

Federal Item Identification Guide (FIIG_4065)

37406

Item Naming Code (INC_4080)

14 Jun 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-103-1559 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNNIND1HZGHKE1 Nov 2005
ZR011 Dec 2007
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-103-1559 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321TXD54529-1  44655   CAGE/44655
525TXRH0012H0500 JDM  24681  
3591TXB265447-1  49956   CAGE/49956
721TX265447-1  3B150   CAGE/3B150
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-103-1559 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX013 Jul 1969
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Jul 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-103-1559 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX657Z9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

657

Water Commodity Code (WRT_CMDTY_CD_9275)


Instruments, Electric Meter

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5905-00-103-1559 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5905-00-103-1559 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.1 lbs0.003 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FA000D3ZZQQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.003 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-103-1559 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEFHEffective Electrical Rotation In Deg Angular Rotation300.0 NOMINAL
CQCCElectrical Resistance Per Section0.5 OHMS SINGLE SECTION
CRSXActuator Travel Control FeatureSTOPS
AEFDActuator TypeSINGLE SHAFT
CSDHAmbient Temp In Deg Celsius Per Section At Full Rated Power25.0 SINGLE SECTION
CQGNAmbient Temp In Deg Celsius Per Section At Zero Percent Rated Power340.0 SINGLE SECTION
ABPMBody Diameter0.875 INCHES NOMINAL
ADAQBody Length0.688 INCHES NOMINAL
AAQLBody StyleCYLINDRICAL BUSHING MOUNTED
ADAPMounting Bushing Length0.250 INCHES NOMINAL
AXGYMounting MethodLOCKING BUSHING
AEFNNonturn Device LocationAT 6 OCLOCK
AEFPNonturn Device Radius0.250 INCHES NOMINAL
CRGDPower Dissipation Rating Per Section In Watts12.5 FREE AIR SINGLE SECTION
AARGReliability IndicatorNOT ESTABLISHED
CRSSResistance Tolerance Per Section In Percent-10.0 TO 10.0 SINGLE SECTION
CQCKRotary Actuator Travel In Angular Deg300.0 NOMINAL
AJYNScrew Thread Diameter0.250 INCHES NOMINAL
AJYQScrew Thread Quantity Per Inch32.0
AJYPScrew Thread Series DesignatorUNEF
AAPNSection Quantity1
ABWVShaft Diameter0.125 INCHES NOMINAL
AEDXShaft StyleROUND, SLOTTED
ABXFShaft Length0.531 INCHES NOMINAL
APXHTerminal LocationRADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE
TTQYTerminal Type And Quantity3 TAB, SOLDER LUG


Back to Top
Back to Top