5905-00-104-0870

RESISTOR,THERMAL


5905-00-104-0870 (5905001040870, 001040870)
Part Numbers (4 listings): 171-002-1801 | TM1/4180K | TM1-418PORM10PC | TM14-180HMSP0RM1 |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 14 Jun 1968

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-104-0870 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
171-002-18013 - Design Control Reference2 - Production ItemKEARFOTT CORPORATION  88818    CAGE 88818  
TM1/4 180K5 - Replaced / Discontinued9 - No Longer UsedTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
TM1-4 18PORM10PCC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
TM14-180HMSP0RM1C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-104-0870 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905001040870A086A000309X1ANBU14 Jun 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

001040870

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-104-0870

A086A0

Federal Item Identification Guide (FIIG_4065)

00309

Item Naming Code (INC_4080)

14 Jun 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-104-0870 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU
ZZ
FXGX3LZSX1 Apr 2006
N9BN3LZGHKE1 Apr 2006
ZU011 Mar 2008
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

L

Acquisition Method Suffix Code (AMSC_2876)


The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-104-0870 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1321TXD171-002-1801  88818   CAGE/88818
59ETXTM1/4 180K  01295   CAGE/01295
C15ZZACTM14-180HMSP0RM1  01295   CAGE/01295
C15ZZACTM1-4 18PORM10PC  01295   CAGE/01295
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-104-0870 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72D39AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5905-00-104-0870 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NEA0
DNSMSJU1EA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-104-0870 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEHYAmbient Temp At Full Rated Power100.0 DEG CELSIUS
ADAQBody Length0.585 INCHES NOMINAL
ADARBody Outside Diameter0.200 INCHES NOMINAL
AEHZMaximum Operating Temp150.0 DEG CELSIUS
AEHXMaximum Power Dissipation Rating250.00 MILLIWATTS
CTGTReference Temp In Deg Celsius25.0
ABDNTerminal Surface TreatmentSOLDER
CQWDZero Power Resistance18.000 OHMS
AKNAInclosure TypeENCAPSULATED
AEJBPower Dissipation Constant In Milliwatts Per Deg Celsius5.0
AARGReliability IndicatorNOT ESTABLISHED
AEJFResistance Tolerance At A Specified Temp In Percent-12.8/+12.8 4TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-14.3/+14.3 7TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-14.6 TO 14.6 3RD RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-15.0/+15.0 2ND RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-16.2 TO 16.2 8TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-16.1 TO 16.1 1ST RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-18.5/+18.5 9TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-20.0 TO 20.0 10TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-10.3/+10.3 5TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-12.1 TO 12.1 6TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp10.4 OHMS 2ND RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp11.3 OHMS 3RD RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp13.3 OHMS 4TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp15.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp20.7 OHMS 6TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp9.7 OHMS 1ST RESISTANCE-TEMPERATURE POINT
CRQJZero Power Resistance Tolerance In Percent At Reference Temp-10.0/+10.0
AEJCZero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius0.70
AEJEZero Power Resistance At Specified Temp24.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp27.5 OHMS 8TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp31.9 OHMS 9TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp35.9 OHMS 10TH RESISTANCE-TEMPERATURE POINT
STYLStyle DesignatorROD
AEJDTemp Points For Resistance Readings At Zero Power-25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-65.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power0.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
AEBTTerminal Diameter0.025 INCHES NOMINAL
ABJTTerminal Length1.500 INCHES NOMINAL
TTQYTerminal Type And Quantity2 WIRE LEAD
AEJAThermal Time Constant In Seconds54.0


Back to Top
Back to Top