| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 805361-1 | 3 - Design Control Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC | 64547 | |
| 200WS-364 | 5 - Replaced / Discontinued | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 08815 | |
| 805361-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 70210 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 001049413 | A002A0 | 37408 | X | 1 | A | N | B | G | 24 Jun 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item contains gold.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| FXGX | FXTX | 1 | R | Z | SX | SX | 1 Jul 2005 | |||||||||||||||||||||||
| N9BN | N9ND | 1 | R | Z | GH | KE | 1 Jul 2005 | |||||||||||||||||||||||
| ZU01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval ICP, Philadelphia, PA 19111
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 1 | KE | 805361-1 | 64547 | | ||||||
| 5 | 2 | 5 | TX | 200WS-364 | 08815 | | ||||||
| 4 | 5 | 9 | 1 | KE | B | 805361-1 | 70210 | | ||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 2 | TX | 0 | 28 Jun 1969 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KE | 72D | 3 | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Naval ICP, Philadelphia, PA 19111
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | ZZ | XXX | 2.5 lbs | 0.714 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| X | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AEFH | Effective Electrical Rotation In Deg Angular Rotation | 349.8 NOMINAL |
| CQCC | Electrical Resistance Per Section | 20.0 KILOHMS 2ND SECTION |
| CQCC | Electrical Resistance Per Section | 2.0 KILOHMS 1ST SECTION |
| CRSX | Actuator Travel Control Feature | STOPS |
| AEFD | Actuator Type | SINGLE SHAFT |
| CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 65.0 ALL SECTIONS |
| CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 125.0 ALL SECTIONS |
| ABPM | Body Diameter | 2.030 INCHES MAXIMUM |
| ADAQ | Body Length | 2.885 INCHES MAXIMUM |
| AAQL | Body Style | CYLINDRICAL SERVO MOUNTED |
| CBBL | Features Provided | SWITCH |
| CRJS | Fixed Tap Quantity Per Section | 1 3RD SECTION |
| CSBX | Function Characteristic Per Section | 1ST SECTION GRAPH |
| CSBX | Function Characteristic Per Section | 4TH SECTION EQUATION |
| CSBX | Function Characteristic Per Section | 2ND SECTION GRAPH |
| CSBX | Function Characteristic Per Section | 3RD SECTION EQUATION |
| CRGM | Function Conformity Per Section | ALL SECTIONS ABSOLUTE CONFORMITY |
| CQFL | Function Conformity Tolerance Per Section | -0.00035 TO 0.00035 4TH SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.01 TO 0.01 3RD SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.25 TO 0.25 1ST SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.25 TO 0.25 2ND SECTION |
| AEFK | Maximum Starting Torque | 2.60 INCH-OUNCES |
| AEGD | Mechanical Backlash In Deg Angular Rotation | 0.1 |
| AEDA | Mounting Lip Depth | 0.0570 INCHES MINIMUM AND 0.0670 INCHES MAXIMUM |
| AECZ | Mounting Lip Diameter | 1.9950 INCHES MINIMUM AND 2.0050 INCHES MAXIMUM |
| AXGY | Mounting Method | CLAMP RING |
| ABHP | Overall Length | 3.625 INCHES NOMINAL |
| PMLC | Precious Material And Location | TERMINAL SURFACES GOLD |
| PRMT | Precious Material | GOLD |
| AEGA | Lateral Runout | 0.004 INCHES |
| CRGD | Power Dissipation Rating Per Section In Watts | 4.0 FREE AIR ALL SECTIONS |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| CRSS | Resistance Tolerance Per Section In Percent | -2.0 TO 2.0 1ST SECTION |
| CRSS | Resistance Tolerance Per Section In Percent | -2.0 TO 2.0 2ND SECTION |
| CRSS | Resistance Tolerance Per Section In Percent | -2.5 TO 2.5 4TH SECTION |
| CRSS | Resistance Tolerance Per Section In Percent | -5.0 TO 5.0 3RD SECTION |
| CQCK | Rotary Actuator Travel In Angular Deg | 360.0 NOMINAL |
| AAPN | Section Quantity | 4 |
| AEDZ | Shaft Bearing Type | BALL |
| ABWV | Shaft Diameter | 0.1869 INCHES MINIMUM AND 0.1872 INCHES MAXIMUM |
| AEFY | Shaft End Play | 0.005 INCHES |
| AEGC | Shaft Radial Play | 0.002 INCHES |
| AEFZ | Shaft Runout | 0.002 INCHES |
| AEDX | Shaft Style | ROUND, SLOTTED |
| ABXF | Shaft Length | 0.630 INCHES MINIMUM AND 0.650 INCHES MAXIMUM |
| AEGB | Pilot Diameter Runout | 0.001 INCHES |
| AAVL | Pilot Diameter | 1.2495 INCHES MINIMUM AND 1.2500 INCHES MAXIMUM |
| AAVM | Pilot Length | 0.0570 INCHES MINIMUM AND 0.0670 INCHES MAXIMUM |
| ABPA | Undercut Diameter | 1.880 INCHES MAXIMUM |
| ABPC | Undercut Width | 0.0570 INCHES MINIMUM |
| AEGJ | Switch Contact Arrangement | SINGLE POLE, SINGLE THROW, NORMALLY OPEN, BOTH POSITIONS MAINTAINED |
| CSDK | Switch Current Type And Rating In Amps | 0.005 DC |
| AEGH | Switch Operating Position | START OF ROTATION |
| AEEA | Switch Type | ROTARY |
| AEED | Switch Voltage Rating In Volts | 28.0 |
| CQCH | Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation | 75.4 3RD SECTION |
| CRKS | Tap Location Tolerance Per Section | -5.0 TO 5.0 DEG ANGULAR ROTATION 3RD SECTION |
| CSCY | Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius | -20.0 TO 20.0 ALL SECTIONS |
| APXH | Terminal Location | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
| TTQY | Terminal Type And Quantity | 15 TURRET |
| TEST | Test Data Document | 70210-805361 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |