| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| TM1-4 15000HMP0RM10PCT | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 96214 | |
| 714-2365-00 | 7 - Vendor Item Drawing Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 001049903 | A086A0 | 00309 | X | 1 | A | N | U | 24 Jun 1968 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 5 | TA | D | TM1-4 15000HMP0RM10PCT | 96214 | | ||||
| 3 | 7 | 2 | 2 | TA | D | 714-2365-00 | 13499 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 3 | TX | 0 | 1 | TX | 0 | 7 Sep 1971 | 5905008566105 | 18 Dec 1973 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | P | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AEHY | Ambient Temp At Full Rated Power | 100.0 DEG CELSIUS |
| ADAQ | Body Length | 0.585 INCHES NOMINAL |
| ADAR | Body Outside Diameter | 0.200 INCHES NOMINAL |
| AEHZ | Maximum Operating Temp | 150.0 DEG CELSIUS |
| AEHX | Maximum Power Dissipation Rating | 250.00 MILLIWATTS |
| CQWD | Zero Power Resistance | 1.500 KILOHMS |
| AKNA | Inclosure Type | ENCAPSULATED |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| AEJF | Resistance Tolerance At A Specified Temp In Percent | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AEJE | Zero Power Resistance At Specified Temp | 1.2 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJE | Zero Power Resistance At Specified Temp | 1.8 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| AEJE | Zero Power Resistance At Specified Temp | 2.5 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJE | Zero Power Resistance At Specified Temp | 2.9 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| CRQJ | Zero Power Resistance Tolerance In Percent At Reference Temp | -10.0 TO 10.0 |
| AEJC | Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius | 0.70 |
| AEJE | Zero Power Resistance At Specified Temp | 3.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJE | Zero Power Resistance At Specified Temp | 675.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| STYL | Style Designator | ROD |
| AEJD | Temp Points For Resistance Readings At Zero Power | -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| AEJD | Temp Points For Resistance Readings At Zero Power | 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| AEJD | Temp Points For Resistance Readings At Zero Power | 0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| AEJD | Temp Points For Resistance Readings At Zero Power | 125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| AEJD | Temp Points For Resistance Readings At Zero Power | 150.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| AEJD | Temp Points For Resistance Readings At Zero Power | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| AEBT | Terminal Diameter | 0.025 INCHES NOMINAL |
| ABJT | Terminal Length | 1.500 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 2 WIRE LEAD |
| AEJA | Thermal Time Constant In Seconds | 60.0 |