5905-00-132-4867

RESISTOR,FIXED,WIRE WOUND,INDUCTIVE


5905-00-132-4867 (5905001324867, 001324867)
Part Numbers (3 listings): 11040569-111 | 3X100LTC1PCT | 242E1011AL |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 30 Dec 1968

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-132-4867 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
11040569-1111 - Source of Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
3X100LTC1PCT3 - Design Control Reference2 - Production ItemWARD LEONARD ELECTRIC COMPANY INC.  63743    CAGE 63743  
242E1011AL5 - Replaced / Discontinued9 - No Longer UsedSPRAGUE ELECTRIC CO  24165      
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-132-4867 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905001324867A001A037403X1ANAU30 Dec 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

001324867

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-132-4867

A001A0

Federal Item Identification Guide (FIIG_4065)

37403

Item Naming Code (INC_4080)

30 Dec 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-132-4867 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Nov 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-132-4867 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3121BDD11040569-111  18876   CAGE/18876
3326BDD3X100LTC1PCT  63743   CAGE/63743
3596BDB242E1011AL  24165  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

BD

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-132-4867 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX03 Feb 1970
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3 Feb 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-132-4867 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
BD723Z9AHZM062800X49770RADIO-TV-RECEIVING-SET-CHASSIS-ETC
Code Definitions

BD

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

M

Less Than Truckload (CLAS_RTNG_CD_2770)


85

062800

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49770

Uniform Freight Classification (UFC_CD_MODF_3040)

RADIO-TV-RECEIVING-SET-CHASSIS-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-132-4867 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPPElectrical Resistance100.000 OHMS
AAQFAmbient Temp In Deg Celsius At Full Rated Power25.0
AAQGAmbient Temp In Deg Celsius At Zero Percent Rated Power340.0
ABPMBody Diameter0.190 INCHES NOMINAL
ADAQBody Length0.500 INCHES NOMINAL
AAQZInclosure MethodENCAPSULATED
AEFBPower Dissipation Rating In Watts3.000 FREE AIR
AARGReliability IndicatorNOT ESTABLISHED
AAPQResistance Tolerance In Percent-1.000/+1.000 LOWEST RESISTANCE VALUE
STYLStyle DesignatorAXIAL TERMINAL EACH END
AAQHTemp Range Of Temp Coefficient In Deg Celsius+250.0/+340.0 TEMP RANGE OF SECOND TEMP COEFFICIENT
AAQHTemp Range Of Temp Coefficient In Deg Celsius-55.0/+250.0 TEMP RANGE OF FIRST TEMP COEFFICIENT
AAPETemp Coefficient Of Resistance In Ppm Per Deg Celsius-30.0/+30.0 FIRST TEMP COEFFICIENT
AAPETemp Coefficient Of Resistance In Ppm Per Deg Celsius-60.0/+60.0 SECOND TEMP COEFFICIENT
AARBTerminal TypeWIRE LEAD
TESTTest Data Document18876-11040569 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Back to Top