| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 412197-14 | 3 - Design Control Reference | 2 - Production Item | NAVAL AIR WARFARE CENTER AIRCRAFT | 80020 | |
| 134FTS107-4 | 5 - Replaced / Discontinued | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 08815 | |
| 22027-4 | 5 - Replaced / Discontinued | 2 - Production Item | SENSOR SYSTEMS, L.L.C. | 04454 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 001340426 | A002A0 | 37405 | X | 1 | A | N | B | U | 25 Aug 1969 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZZ | ||||||||||||||||||||||||||||||
| N9BN | 1 | C | Z | GH | GT | KE | HD | 1 Apr 2006 | ||||||||||||||||||||||
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 1 | TX | D | 412197-14 | 80020 | | ||||
| 5 | 2 | 5 | ZZ | 22027-4 | 04454 | | ||||||
| 5 | 2 | 5 | TX | 134FTS107-4 | 08815 | | ||||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | 72D | 3 | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AEFH | Effective Electrical Rotation In Deg Angular Rotation | 165.0 MINIMUM AND 175.0 MAXIMUM |
| CQCC | Electrical Resistance Per Section | 4.25 KILOHMS 2ND SECTION |
| CQCC | Electrical Resistance Per Section | 8.5 KILOHMS 1ST SECTION |
| CRSX | Actuator Travel Control Feature | CONTINUOUS MOTION |
| AEFD | Actuator Type | SINGLE SHAFT |
| CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 55.0 ALL SECTIONS |
| CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 85.0 ALL SECTIONS |
| ABPM | Body Diameter | 1.767 INCHES MAXIMUM |
| ADAQ | Body Length | 0.977 INCHES MAXIMUM |
| AAQL | Body Style | CYLINDRICAL SERVO MOUNTED |
| AEEZ | Contact Arm Electrical Off Position | FULLY CCW-CW |
| CBBL | Features Provided | NONMETALLIC SHAFT |
| CRJS | Fixed Tap Quantity Per Section | 1 1ST SECTION |
| AEDA | Mounting Lip Depth | 0.0930 INCHES NOMINAL |
| AECZ | Mounting Lip Diameter | 1.7670 INCHES MAXIMUM |
| AXGY | Mounting Method | CLAMP RING |
| ADAV | Overall Diameter | 2.120 INCHES MAXIMUM |
| ABHP | Overall Length | 2.230 INCHES MAXIMUM |
| CRGD | Power Dissipation Rating Per Section In Watts | 4.0 FREE AIR ALL SECTIONS |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| CRSS | Resistance Tolerance Per Section In Percent | -5.0 TO 5.0 ALL SECTIONS |
| CQCK | Rotary Actuator Travel In Angular Deg | 360.0 NOMINAL |
| AAPN | Section Quantity | 2 |
| ABWV | Shaft Diameter | 0.125 INCHES NOMINAL |
| AEDX | Shaft Style | ROUND |
| ABXF | Shaft Length | 0.562 INCHES NOMINAL |
| AAVL | Pilot Diameter | 1.5620 INCHES MAXIMUM |
| AAVM | Pilot Length | 0.0620 INCHES NOMINAL |
| ABPA | Undercut Diameter | 1.750 INCHES MAXIMUM |
| ABPC | Undercut Width | 0.0780 INCHES NOMINAL |
| CSBW | Tap Location From Ccw Terminal Per Section In Ohms | 4250.0 1ST SECTION |
| CRKS | Tap Location Tolerance Per Section | -1.0 TO 1.0 OHMS 1ST SECTION |
| CRFJ | Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius | -300.0 TO 300.0 ALL SECTIONS |
| APXH | Terminal Location | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
| TTQY | Terminal Type And Quantity | 7 TAB, SOLDER LUG |
| TEST | Test Data Document | 80020-41297 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |