| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 3001155-7 | 3 - Design Control Reference | 2 - Production Item | CETEC CORP | 23427 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 001966798 | X | A | N | A | U | 17 Jun 1970 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
NSN Center Does Not Have An Explanation
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | 22 Mar 1992 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 1 | TX | D | 3001155-7 | 23427 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 3 | TX | 1 | 1 | TX | 0 | 13 Jun 1966 | 5905006435626 | 15 Jun 1985 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 96 |
DLIS-LFF, Battle Creek, MI 49037-3084
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPN | Section Quantity | 1 |
| CQCC | Electrical Resistance Per Section | 5.000 KILOHMS SINGLE SECTION |
| CRSS | Resistance Tolerance Per Section In Percent | -20.0 TO 20.0 SINGLE SECTION |
| CSDL | Standard Taper Curve Per Section | A SINGLE SECTION |
| CQDB | Resistance Temp Characteristic Range Per Section In Percent | -3.0 TO 0.0 -55 DEG CELSIUS SINGLE SECTION AND |
| CQDB | Resistance Temp Characteristic Range Per Section In Percent | -5.0 TO 10.0 -25 DEG CELSIUS SINGLE SECTION AND |
| CQDB | Resistance Temp Characteristic Range Per Section In Percent | -5.0 TO 10.0 25 DEG CELSIUS SINGLE SECTION AND |
| CQDB | Resistance Temp Characteristic Range Per Section In Percent | 0.0 TO 3.0 120 DEG CELSIUS SINGLE SECTION |
| CRGD | Power Dissipation Rating Per Section In Watts | 2.0 FREE AIR SINGLE SECTION |
| CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 70.0 SINGLE SECTION |
| CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 120.0 SINGLE SECTION |
| AAQL | Body Style | CYLINDRICAL BUSHING MOUNTED |
| ABPM | Body Diameter | 1.094 INCHES NOMINAL |
| ADAQ | Body Length | 0.453 INCHES NOMINAL |
| ADAP | Mounting Bushing Length | 0.375 INCHES NOMINAL |
| AEFD | Actuator Type | SINGLE SHAFT |
| AEDX | Shaft Style | ROUND |
| ABWV | Shaft Diameter | 0.250 INCHES NOMINAL |
| ABXF | Shaft Length | 0.750 INCHES NOMINAL |
| CQCK | Rotary Actuator Travel In Angular Deg | 312.0 NOMINAL |
| CRSX | Actuator Travel Control Feature | STOPS |
| AEFH | Effective Electrical Rotation In Deg Angular Rotation | 312.0 NOMINAL |
| AEFN | Nonturn Device Location | AT 9 OCLOCK |
| AEFP | Nonturn Device Radius | 0.438 INCHES NOMINAL |
| AXGY | Mounting Method | STANDARD BUSHING |
| AJYP | Screw Thread Series Designator | UNEF |
| AJYN | Screw Thread Diameter | 0.375 INCHES NOMINAL |
| AJYQ | Screw Thread Quantity Per Inch | 32.0 |
| TTQY | Terminal Type And Quantity | 3 TAB, SOLDER LUG |
| APXH | Terminal Location | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |