| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 002335927 | A001A0 | 05311 | X | 1 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZW01 | 1 Sep 2009 | |||||||||||||||||||||||||||||
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | TX | 0 | 15 Dec 1974 |
An item authorized for procurement that has not yet been subject to item standardization.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPP | Electrical Resistance | 23.300 OHMS |
| AAPQ | Resistance Tolerance In Percent | -1.000 TO 1.000 |
| AEFB | Power Dissipation Rating In Watts | 0.500 FREE AIR |
| AAPE | Temp Coefficient Of Resistance In Ppm Per Deg Celsius | -400.0 TO 400.0 |
| AAQH | Temp Range Of Temp Coefficient In Deg Celsius | -55.0 TO 100.0 |
| AAQZ | Inclosure Method | ENCAPSULATED |
| STYL | Style Designator | RADIAL TERMINAL EACH END |
| ADAQ | Body Length | 0.625 INCHES NOMINAL |
| AARB | Terminal Type | WIRE LEAD |
| AARG | Reliability Indicator | NOT ESTABLISHED |