5905-00-279-1871

RESISTOR,FIXED,COMPOSITION


5905-00-279-1871 (5905002791871, 002791871)
Part Numbers (13 listings): RC20GF164J | MILR11 | 311-002-102 | 560B4GF164 | 4171300-122 | 280-1145P153 | 0524-102 | 0686-1645 | 301-0164-00 | 5N5102-011-27 | 5027-543 | 301-164 | RES160K00005%0,50WAG04X010 |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

5905-00-114-5378

Replacement Date: 17 Nov 1968

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-279-1871 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RC20GF164J2 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MILR114 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
311-002-1025 - Replaced / Discontinued1 - Incomplete Part NumberINTERSTATE ELECTRONICS CORPORATION  07421    CAGE 07421  
560B4GF1645 - Replaced / Discontinued1 - Incomplete Part NumberCARDWELL CONDENSER CORP  94033    CAGE 94033  
4171300-1225 - Replaced / Discontinued1 - Incomplete Part NumberRAYTHEON COMPANY  82577    CAGE 82577  
4171300-1225 - Replaced / Discontinued1 - Incomplete Part NumberRAYTHEON COMPANY  05869    CAGE 05869  
280-1145P1535 - Replaced / Discontinued1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
0524-1025 - Replaced / Discontinued1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  56232    CAGE 56232  
0686-16455 - Replaced / Discontinued1 - Incomplete Part NumberAGILENT TECHNOLOGIES, INC.  1MY97    CAGE 1MY97  
301-0164-005 - Replaced / Discontinued1 - Incomplete Part NumberTEKTRONIX, INC.  80009    CAGE 80009  
5N5102-011-275 - Replaced / Discontinued2 - Production ItemEADS DEUTSCHLAND GMBH  D1901    CAGE D1901  
5027-5435 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
301-1645 - Replaced / Discontinued9 - No Longer UsedTEKTRONIX, INC.  80009    CAGE 80009  
0686-16455 - Replaced / Discontinued9 - No Longer UsedHEWLETT PACKARD CO  28480    CAGE 28480  
RES 160K00 005% 0,50WAG04X0105 - Replaced / Discontinued9 - No Longer UsedDIRECTION CENTRALE DU MATERIEL DE  F3033    CAGE F3033  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-279-1871 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905002791871A001A000126X49ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

002791871

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-279-1871

A001A0

Federal Item Identification Guide (FIIG_4065)

00126

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-279-1871 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G41000L1 Apr 1991
YB011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZH011 Apr 1991
ZP011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 1998
YW011 Aug 2000
YA011 Dec 2001
WB011 Feb 2005
ZG011 Nov 2011
YK011 Feb 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-279-1871 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
51448560B4GF164  94033   CAGE/94033
3514HDD311-002-102  07421   CAGE/07421
514ZZ0686-1645  1MY97   CAGE/1MY97
3521ZGD5N5102-011-27  D1901   CAGE/D1901
3524ZFD5027-543  82577   CAGE/82577
594ZFBRES 160K00 005% 0,50WAG04X010  F3033   CAGE/F3033
159575B301-164  80009   CAGE/80009
359448B0686-1645  28480   CAGE/28480
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

ZF

Reference Number Action Activity Code (RNAAC_2900)


France

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-279-1871 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX01TX017 Nov 1968 5905001145378 3 Dec 1969
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

17 Nov 1968

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-114-5378

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3 Dec 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-279-1871 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-279-1871 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPPElectrical Resistance160.000 KILOHMS
AAQFAmbient Temp In Deg Celsius At Full Rated Power70.0
AAQGAmbient Temp In Deg Celsius At Zero Percent Rated Power130.0
ABPMBody Diameter0.138 INCHES NOMINAL
ADAQBody Length0.375 INCHES NOMINAL
AAQZInclosure MethodENCAPSULATED
AEFBPower Dissipation Rating In Watts0.500 FREE AIR
AAPQResistance Tolerance In Percent-5.000/+5.000
STYLStyle DesignatorAXIAL TERMINAL EACH END
AARBTerminal TypeWIRE LEAD
TESTTest Data Document81349-MIL-R-11/3 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top