5905-00-421-0817

RESISTOR,THERMAL


5905-00-421-0817 (5905004210817, 004210817)
Part Number (1 listing): GA51J1
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 12 Mar 1969

Unit Weight: None

Unit Size:

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-421-0817 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GA51J13 - Design Control Reference9 - No Longer UsedBAXTER HEALTHCARE CORPORATION  02606      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-421-0817 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905004210817A086A000309X1ANU12 Mar 1969
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

004210817

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-421-0817

A086A0

Federal Item Identification Guide (FIIG_4065)

00309

Item Naming Code (INC_4080)

12 Mar 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-421-0817 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZK011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-421-0817 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3396KEDGA51J1  02606  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-421-0817 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX08 Sep 1971
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

8 Sep 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-421-0817 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5905-00-421-0817 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5905-00-421-0817 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP411AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
FA000D1QQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-421-0817 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEHYAmbient Temp At Full Rated Power25.0 DEG CELSIUS
ADAQBody Length0.043 INCHES NOMINAL
ADARBody Outside Diameter0.043 INCHES NOMINAL
CBMECubic Measure0.00005 CUBIC INCHES
AEHZMaximum Operating Temp300.0 DEG CELSIUS
CQWDZero Power Resistance100.000 KILOHMS
AKNAInclosure TypeENCAPSULATED
AEJBPower Dissipation Constant In Milliwatts Per Deg Celsius0.4
CTGTReference Temp In Deg Celsius25.0
AEJFResistance Tolerance At A Specified Temp In Percent-15.7/+15.7 4TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-17.5/+17.5 3RD RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-18.4/+18.4 5TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-20.6/+20.6 6TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-21.2/+21.2 2ND RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-22.6/+22.6 7TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-24.3/+24.3 8TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-25.8/+25.8 1ST RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-26.8/+26.8 9TH RESISTANCE-TEMPERATURE POINT
AEJFResistance Tolerance At A Specified Temp In Percent-30.4/+30.4 10TH RESISTANCE-TEMPERATURE POINT
AARGReliability IndicatorNOT ESTABLISHED
PKWTUnpackaged Unit Weight0.200 GRAMS
AEJEZero Power Resistance At Specified Temp1.7 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp1.8 MEGOHMS 2ND RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp117.3 OHMS 10TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp15.2 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp8.7 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp80.3 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
CRQJZero Power Resistance Tolerance In Percent At Reference Temp-15.0/+15.0
AEJCZero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius-4.50
AEJEZero Power Resistance At Specified Temp24.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp3.6 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp336.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
AEJEZero Power Resistance At Specified Temp576.9 OHMS 9TH RESISTANCE-TEMPERATURE POINT
STYLStyle DesignatorSEALED OR COATED BEAD
AEJDTemp Points For Resistance Readings At Zero Power300.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power30.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power60.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power90.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power-60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power120.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power150.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
AEJDTemp Points For Resistance Readings At Zero Power200.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
AEBTTerminal Diameter0.004 INCHES NOMINAL
ABJTTerminal Length0.375 INCHES NOMINAL
TTQYTerminal Type And Quantity2 WIRE LEAD
ABDNTerminal Surface TreatmentSOLDER
AEJAThermal Time Constant In Seconds4.0


Back to Top
Back to Top