| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 176WS296 | 3 - Design Control Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 08815 | |
| 2996543-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 004447744 | A002A0 | 37408 | X | 1 | A | N | B | A | 30 Dec 1970 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N9BN | N9ND | 3 | L | Z | HD | HD | 1 Apr 2006 | |||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 5 | HH | D | 176WS296 | 08815 | | ||||
| 3 | 7 | 2 | 1 | HH | D | 2996543-1 | 10001 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Navy ICP, Mechanicsburg, PA 17055-0788
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 2 | TX | 0 | 8 Sep 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HH | 72D | 3 | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Navy ICP, Mechanicsburg, PA 17055-0788
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | ZZ | XXX |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPN | Section Quantity | 4 |
| CQCC | Electrical Resistance Per Section | 10.000 KILOHMS 1ST SECTION |
| CQCC | Electrical Resistance Per Section | 10.000 KILOHMS 2ND SECTION |
| CQCC | Electrical Resistance Per Section | 20.000 KILOHMS 3RD SECTION |
| CQCC | Electrical Resistance Per Section | 20.000 KILOHMS 4TH SECTION |
| CRSS | Resistance Tolerance Per Section In Percent | -5.0 TO 5.0 ALL SECTIONS |
| CRGM | Function Conformity Per Section | 1ST SECTION ABSOLUTE LINEARITY |
| CRGM | Function Conformity Per Section | 2ND SECTION ABSOLUTE LINEARITY |
| CRGM | Function Conformity Per Section | 3RD SECTION ABSOLUTE LINEARITY |
| CRGM | Function Conformity Per Section | 4TH SECTION ABSOLUTE CONFORMITY |
| CSBX | Function Characteristic Per Section | 1ST SECTION LINEAR |
| CSBX | Function Characteristic Per Section | 2ND SECTION LINEAR |
| CSBX | Function Characteristic Per Section | 3RD SECTION LINEAR |
| CSBX | Function Characteristic Per Section | 4TH SECTION GRAPH |
| CQFL | Function Conformity Tolerance Per Section | -0.15 TO 0.15 1ST SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.30 TO 0.30 2ND SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.50 TO 0.50 3RD SECTION |
| CQFL | Function Conformity Tolerance Per Section | -0.50 TO 0.50 4TH SECTION |
| AEDZ | Shaft Bearing Type | BALL |
| AEFK | Maximum Starting Torque | 3.25 INCH-OUNCES |
| AEFL | Maximum Running Torque | 3.00 INCH-OUNCES |
| CSCY | Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius | -20.0 TO 20.0 ALL SECTIONS |
| CRGD | Power Dissipation Rating Per Section In Watts | 2.0 FREE AIR ALL SECTIONS |
| CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 85.0 ALL SECTIONS |
| CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 125.0 ALL SECTIONS |
| AAQL | Body Style | CYLINDRICAL SERVO MOUNTED |
| AAVL | Pilot Diameter | 1.3125 INCHES MAXIMUM |
| AAVM | Pilot Length | 0.0620 INCHES NOMINAL |
| ABPA | Undercut Diameter | 1.313 INCHES MAXIMUM |
| ABPC | Undercut Width | 0.0730 INCHES MINIMUM |
| ABPM | Body Diameter | 1.440 INCHES MAXIMUM |
| ADAQ | Body Length | 2.300 INCHES MAXIMUM |
| AECZ | Mounting Lip Diameter | 1.4370 INCHES NOMINAL |
| AEDA | Mounting Lip Depth | 0.0930 INCHES NOMINAL |
| AEFD | Actuator Type | DOUBLE ENDED SHAFT |
| AEDX | Shaft Style | ROUND, SLOTTED |
| ABWV | Shaft Diameter | 0.2497 INCHES MAXIMUM |
| ABXF | Shaft Length | 0.680 INCHES NOMINAL |
| CQCK | Rotary Actuator Travel In Angular Deg | 360.0 NOMINAL |
| CRSX | Actuator Travel Control Feature | CONTINUOUS MOTION |
| AEFH | Effective Electrical Rotation In Deg Angular Rotation | 345.0 NOMINAL |
| AXGY | Mounting Method | CLAMP RING |
| TTQY | Terminal Type And Quantity | 12 TURRET |
| APXH | Terminal Location | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| FEAT | Special Features | REAR SLOTTED SHAFT,SHAFT LENGTH 0.250 INCHES MAXIMUM,SHAFT DIAMETER 0.3125 INCHES MAXIMUM |
| TEST | Test Data Document | 10001-2996543 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| ABHP | Overall Length | 3.250 INCHES MAXIMUM |
| ADAV | Overall Diameter | 1.880 INCHES MAXIMUM |
| CBME | Cubic Measure | 3.745 CUBIC INCHES |