| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 912058-1 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN GUIDANCE AND | 06481 | |
| 182766-1 | 5 - Replaced / Discontinued | 2 - Production Item | SHALLCROSS INC | 54294 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 004712352 | A001A0 | 32069 | X | 1 | A | N | B | U | 28 Aug 1970 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YJ | ||||||||||||||||||||||||||||||
| ZZ | ||||||||||||||||||||||||||||||
| A918 | 3 | L | Z | CD | CL | 1 Apr 2006 | ||||||||||||||||||||||||
| N9BN | 3 | L | Z | GH | KE | 1 Apr 2006 | ||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | 1 | TX | D | 912058-1 | 06481 | | ||||
| 3 | 5 | 2 | 5 | TX | D | 182766-1 | 54294 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | 72D | 3 | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPP | Electrical Resistance | 2.82843 KILOHMS |
| AAPP | Electrical Resistance | 2.88384 KILOHMS |
| AAPP | Electrical Resistance | 26.2741 KILOHMS |
| AAPP | Electrical Resistance | 3.06147 KILOHMS |
| AAPP | Electrical Resistance | 3.40172 KILOHMS |
| AAPP | Electrical Resistance | 104.086 KILOHMS |
| AAPP | Electrical Resistance | 11.8673 KILOHMS |
| AAPP | Electrical Resistance | 14.498 KILOHMS |
| AAPP | Electrical Resistance | 6.82843 KILOHMS |
| AAPP | Electrical Resistance | 7.39104 KILOHMS |
| AAPP | Electrical Resistance | 4.000 KILOHMS |
| AAPP | Electrical Resistance | 5.09103 KILOHMS |
| AAQF | Ambient Temp In Deg Celsius At Full Rated Power | 25.0 |
| AAQG | Ambient Temp In Deg Celsius At Zero Percent Rated Power | 125.0 |
| ADAU | Body Height | 0.320 INCHES MAXIMUM |
| ADAQ | Body Length | 1.200 INCHES MAXIMUM |
| ADAT | Body Width | 1.100 INCHES MAXIMUM |
| CQRD | Identical Value Resistor Quantity | 1 6TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 1 LOWEST RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 9TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 HIGHEST RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 10TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 1ST INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 2ND INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 3RD INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 4TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 5TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 7TH INTERMEDIATE RESISTANCE VALUE |
| CQRD | Identical Value Resistor Quantity | 2 8TH INTERMEDIATE RESISTANCE VALUE |
| AAQZ | Inclosure Method | ENCAPSULATED |
| AEFB | Power Dissipation Rating In Watts | 0.250 EACH RESISTOR |
| AAPQ | Resistance Tolerance In Percent | -1.000/+1.000 |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| AEBZ | Schematic Diagram Designator | SERIES NETWORK |
| STYL | Style Designator | FLAT PACK |
| AAQH | Temp Range Of Temp Coefficient In Deg Celsius | -55.0/+125.0 |
| AAPE | Temp Coefficient Of Resistance In Ppm Per Deg Celsius | -600.0/+600.0 |
| ABJT | Terminal Length | 0.500 INCHES MINIMUM |
| AARA | Terminal Quantity | 11 |
| AARB | Terminal Type | PIN |