5905-00-474-2364

RESISTOR,FIXED,FILM


5905-00-474-2364 (5905004742364, 004742364)
Part Number (1 listing): 10668633-252
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 7

HMIC: N

Date Created: 9 Jun 1974

Replacement NSN:

5905-00-099-0479

Replacement Date: 17 Dec 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-474-2364 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
10668633-2523 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
10668633-2523 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-474-2364 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905004742364A001A005311X1ANU9 Jun 1974
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

004742364

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-474-2364

A001A0

Federal Item Identification Guide (FIIG_4065)

05311

Item Naming Code (INC_4080)

9 Jun 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-474-2364 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332ATXD10668633-252  18876   CAGE/18876
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-474-2364 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX6BTX017 Dec 1972 5905000990479 20 Jun 1980
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Dec 1972

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-099-0479

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

20 Jun 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-474-2364 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
BDP658Z2AHYP062960X35140REOSTATS-PARTS-NOI
Code Definitions

BD

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

2

Special Handling Code (SP_HDLG_CD_9240)


Classified

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Y

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-474-2364 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPPElectrical Resistance20.500 KILOHMS
AAQFAmbient Temp In Deg Celsius At Full Rated Power70.0
AAQGAmbient Temp In Deg Celsius At Zero Percent Rated Power175.0
ABPMBody Diameter0.156 INCHES MAXIMUM
ADAQBody Length0.480 INCHES MAXIMUM
AAQZInclosure MethodENCAPSULATED
AEFBPower Dissipation Rating In Watts0.250 FREE AIR
AAPQResistance Tolerance In Percent-1.000/+1.000
AARGReliability IndicatorNOT ESTABLISHED
STYLStyle DesignatorAXIAL TERMINAL EACH END
AAQHTemp Range Of Temp Coefficient In Deg Celsius-55.0/+175.0
AAPETemp Coefficient Of Resistance In Ppm Per Deg Celsius-50.0/+50.0
ABJTTerminal Length1.370 INCHES MINIMUM
AARBTerminal TypeWIRE LEAD


Back to Top