Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
271L1-103 | 3 - Design Control Reference | 9 - No Longer Used | BOURNS INSTRUMENTS INC | 80294 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 004821854 | A002A0 | 37406 | X | 4 | 4 | A | N | A | U | 14 Mar 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 4 | 75 | D | 271L1-103 | 80294 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
GSA, FSS/FCSC Washington, DC 20406
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 3 Jan 1971 | 5905007344023 | 1 Oct 1999 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQCC | Electrical Resistance Per Section | 10.000 KILOHMS SINGLE SECTION |
CRSX | Actuator Travel Control Feature | CONTINUOUS MOTION |
AEFD | Actuator Type | SINGLE SHAFT |
CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 25.0 SINGLE SECTION |
CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 105.0 SINGLE SECTION |
ADAU | Body Height | 0.296 INCHES MINIMUM AND 0.328 INCHES MAXIMUM |
ADAQ | Body Length | 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM |
ADAT | Body Width | 0.234 INCHES MINIMUM AND 0.266 INCHES MAXIMUM |
AAQL | Body Style | RECTANGULAR W/MOUNTING HOLES/SLOTS |
AEEZ | Contact Arm Electrical Off Position | FULLY CCW |
CRGM | Function Conformity Per Section | SINGLE SECTION INDEPENDENT LINEARITY |
AKPV | Mounting Facility Quantity | 2 |
ABTB | Mounting Hole Diameter | 0.081 INCHES MINIMUM AND 0.091 INCHES MAXIMUM |
AXGY | Mounting Method | UNTHREADED HOLE |
ABKW | Overall Height | 0.296 INCHES MINIMUM AND 0.328 INCHES MAXIMUM |
ABHP | Overall Length | 1.315 INCHES MINIMUM AND 1.357 INCHES MAXIMUM |
ABMK | Overall Width | 0.234 INCHES MINIMUM AND 0.266 INCHES MAXIMUM |
AGTP | Lateral Distance Between Mounting Hole Centers | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
CRGD | Power Dissipation Rating Per Section In Watts | 0.50 FREE AIR SINGLE SECTION |
CRSS | Resistance Tolerance Per Section In Percent | -10.0 TO 10.0 SINGLE SECTION |
CQCK | Rotary Actuator Travel In Angular Deg | 9000.0 NOMINAL |
AAPN | Section Quantity | 1 |
ABWV | Shaft Diameter | 0.109 INCHES MINIMUM AND 0.141 INCHES MAXIMUM |
ABXF | Shaft Length | 0.081 INCHES MINIMUM AND 0.091 INCHES MAXIMUM |
AEDX | Shaft Style | ROUND, SLOTTED |
CSCY | Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius | -20.0 TO 20.0 SINGLE SECTION |
ABJT | Terminal Length | 11.484 INCHES MINIMUM AND 11.516 INCHES MAXIMUM |
APXH | Terminal Location | REAR END |
TTQY | Terminal Type And Quantity | 3 WIRE LEAD |