5905-00-501-9251

RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION


5905-00-501-9251 (5905005019251, 005019251)
Part Number (1 listing): JA1N040S105MA
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

Replacement NSN:

5905-00-542-8051

Replacement Date: 13 Jun 1966

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-501-9251 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
JA1N040S105MA3 - Design Control Reference2 - Production ItemROCKWELL AUTOMATION, INC.  01121    CAGE 01121  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-501-9251 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905005019251XANAU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

005019251

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-501-9251

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-501-9251 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5905-00-501-9251 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3326TXDJA1N040S105MA  01121   CAGE/01121
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-501-9251 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX013 Jun 1966 5905005428051 22 Jun 1967
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Jun 1966

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-542-8051

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

22 Jun 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-501-9251 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
96
P658Z9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

96

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-LFF, Battle Creek, MI 49037-3084

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-501-9251 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPNSection Quantity1
CQCCElectrical Resistance Per Section1.000 MEGOHMS SINGLE SECTION
CRSSResistance Tolerance Per Section In Percent-20.0 TO 20.0 SINGLE SECTION
CSDLStandard Taper Curve Per SectionA SINGLE SECTION
AEDZShaft Bearing TypeSLEEVE
AEFKMaximum Starting Torque6.00 INCH-OUNCES
AEFLMaximum Running Torque6.00 INCH-OUNCES
CQDBResistance Temp Characteristic Range Per Section In Percent0.0 TO 10.0 -55 DEG CELSIUS SINGLE SECTION AND
CQDBResistance Temp Characteristic Range Per Section In Percent0.0 TO 5.0 -25 DEG CELSIUS SINGLE SECTION AND
CQDBResistance Temp Characteristic Range Per Section In Percent0.0 TO 2.5 0 DEG CELSIUS SINGLE SECTION AND
CQDBResistance Temp Characteristic Range Per Section In Percent0.0 TO 3.5 85 DEG CELSIUS SINGLE SECTION AND
CQDBResistance Temp Characteristic Range Per Section In Percent0.0 TO 7.5 120 DEG CELSIUS SINGLE SECTION
CRGDPower Dissipation Rating Per Section In Watts2.25 FREE AIR SINGLE SECTION
CSDHAmbient Temp In Deg Celsius Per Section At Full Rated Power70.0 SINGLE SECTION
CQGNAmbient Temp In Deg Celsius Per Section At Zero Percent Rated Power120.0 SINGLE SECTION
AAQLBody StyleCYLINDRICAL BUSHING MOUNTED
ABPMBody Diameter1.156 INCHES MAXIMUM
ADAQBody Length0.625 INCHES MAXIMUM
ADAPMounting Bushing Length0.375 INCHES NOMINAL
AEFDActuator TypeSINGLE SHAFT
AEDXShaft StyleROUND, SLOTTED
ABWVShaft Diameter0.250 INCHES NOMINAL
ABXFShaft Length0.625 INCHES NOMINAL
CQCKRotary Actuator Travel In Angular Deg312.0 NOMINAL
CRSXActuator Travel Control FeatureSTOPS
AEFHEffective Electrical Rotation In Deg Angular Rotation292.0 NOMINAL
AEFNNonturn Device LocationAT 9 OCLOCK
AEFPNonturn Device Radius0.531 INCHES NOMINAL
AXGYMounting MethodSTANDARD BUSHING
AJYPScrew Thread Series DesignatorUNEF
AJYNScrew Thread Diameter0.375 INCHES NOMINAL
AJYQScrew Thread Quantity Per Inch32.0
TTQYTerminal Type And Quantity3 TAB, SOLDER LUG
APXHTerminal LocationRADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE
AARGReliability IndicatorNOT ESTABLISHED
ABHPOverall Length1.250 INCHES NOMINAL
ADAVOverall Diameter1.750 INCHES NOMINAL


Back to Top