5905-00-761-5398

RESISTOR,VARIABLE,WIRE WOUND,NONPRECISION


5905-00-761-5398 (5905007615398, 007615398)
Part Numbers (2 listings): RT11C2P103 | MILR27208-3 |
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1960

Replacement NSN:

5905-00-137-0545

Replacement Date: 29 Nov 2001

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-00-761-5398 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RT11C2P1032 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MILR27208-34 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5905-00-761-5398 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905007615398A002A037406X49ANAU1 Jan 1960
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

007615398

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-00-761-5398

A002A0

Federal Item Identification Guide (FIIG_4065)

37406

Item Naming Code (INC_4080)

1 Jan 1960

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-00-761-5398 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZR011 Jul 1997
YA011 Feb 2001
WB011 Feb 2005
ZG011 Mar 2011
YY011 Feb 2015
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-00-761-5398 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX029 Nov 2001 5905001370545 29 Nov 2001
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

29 Nov 2001

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-137-0545

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

29 Nov 2001

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-00-761-5398 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-00-761-5398 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEFHEffective Electrical Rotation In Deg Angular Rotation6120.0 MINIMUM AND 9720.0 MAXIMUM
CQCCElectrical Resistance Per Section10.000 KILOHMS SINGLE SECTION
CRSXActuator Travel Control FeatureSTOPS
AEFDActuator TypeSINGLE SHAFT
CSDHAmbient Temp In Deg Celsius Per Section At Full Rated Power85.0 SINGLE SECTION
CQGNAmbient Temp In Deg Celsius Per Section At Zero Percent Rated Power150.0 SINGLE SECTION
ADAUBody Height0.280 INCHES MINIMUM AND 0.360 INCHES MAXIMUM
ADAQBody Length1.218 INCHES MINIMUM AND 1.282 INCHES MAXIMUM
ADATBody Width0.250 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
AAQLBody StyleRECTANGULAR W/MOUNTING HOLES/SLOTS
CQCMCenter To Center Distance Between Center Terminal And Outside Terminal0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
AEHTCenter To Center Distance Between Terminals0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM
AYQRCenter To Center Distance Between Terminal Rows0.100 INCHES NOMINAL
AEEZContact Arm Electrical Off PositionFULLY CCW
AEFKMaximum Starting Torque8.00 INCH-OUNCES
AKPVMounting Facility Quantity2
ABTBMounting Hole Diameter0.088 INCHES MINIMUM AND 0.098 INCHES MAXIMUM
AXGYMounting MethodUNTHREADED HOLE
ABKWOverall Height0.749 INCHES MINIMUM AND 0.891 INCHES MAXIMUM
ABMKOverall Width0.250 INCHES MINIMUM AND 0.300 INCHES MAXIMUM
ABHPOverall Length1.723 INCHES MINIMUM AND 1.877 INCHES MAXIMUM
AGTPLateral Distance Between Mounting Hole Centers0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM
CRGDPower Dissipation Rating Per Section In Watts0.75 FREE AIR SINGLE SECTION
AARGReliability IndicatorNOT ESTABLISHED
CRSSResistance Tolerance Per Section In Percent-5.0 TO 5.0 SINGLE SECTION
CQCKRotary Actuator Travel In Angular Deg6120.0 MINIMUM AND 9720.0 MAXIMUM
AAPNSection Quantity1
ABWVShaft Diameter0.100 INCHES MINIMUM AND 0.130 INCHES MAXIMUM
ABXFShaft Length0.036 INCHES MINIMUM AND 0.064 INCHES MAXIMUM
AEDXShaft StyleROUND, SLOTTED
CRFJTemp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius-50.0 TO 50.0 SINGLE SECTION
APXHTerminal LocationREAR END
ABJTTerminal Length0.469 INCHES MINIMUM AND 0.531 INCHES MAXIMUM
TTQYTerminal Type And Quantity3 PIN
TESTTest Data Document81349-MILR27208-3 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top