Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
RH103M | 3 - Design Control Reference | 1 - Incomplete Part Number | ROCKWELL AUTOMATION, INC. | 01121 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 008494321 | X | A | N | A | A | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
NSN Center Does Not Have An Explanation
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 5 Nov 2012 | 5905004771253 | 5 Nov 2012 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
96 | |||||||||||||||
DLIS-LFF, Battle Creek, MI 49037-3084
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Department of the Army
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CQCC | Electrical Resistance Per Section | 10.000 KILOHMS SINGLE SECTION |
CRSX | Actuator Travel Control Feature | CLUTCH |
AEFD | Actuator Type | SINGLE SHAFT |
CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 70.0 SINGLE SECTION |
CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 125.0 SINGLE SECTION |
ADAU | Body Height | 0.312 INCHES MINIMUM AND 0.344 INCHES MAXIMUM |
ADAQ | Body Length | 1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM |
ADAT | Body Width | 0.234 INCHES MINIMUM AND 0.266 INCHES MAXIMUM |
AAQL | Body Style | RECTANGULAR W/MOUNTING HOLES/SLOTS |
CQCM | Center To Center Distance Between Center Terminal And Outside Terminal | 0.295 INCHES MINIMUM AND 0.305 INCHES MAXIMUM |
AEHT | Center To Center Distance Between Terminals | 0.305 INCHES MINIMUM AND 0.695 INCHES MAXIMUM |
AYQR | Center To Center Distance Between Terminal Rows | 0.100 INCHES NOMINAL |
AEFK | Maximum Starting Torque | 8.00 INCH-OUNCES |
AKPV | Mounting Facility Quantity | 2 |
ABTB | Mounting Hole Diameter | 0.078 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
AXGY | Mounting Method | UNTHREADED HOLE |
ABKW | Overall Height | 0.922 INCHES NOMINAL |
ABHP | Overall Length | 1.375 INCHES NOMINAL |
AGTP | Lateral Distance Between Mounting Hole Centers | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
CRGD | Power Dissipation Rating Per Section In Watts | 0.25 FREE AIR SINGLE SECTION |
AARG | Reliability Indicator | NOT ESTABLISHED |
CRSS | Resistance Tolerance Per Section In Percent | -20.0 TO 20.0 SINGLE SECTION |
CQCK | Rotary Actuator Travel In Angular Deg | 7920.0 MINIMUM AND 10080.0 MAXIMUM |
AAPN | Section Quantity | 1 |
ABWV | Shaft Diameter | 0.140 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
ABXF | Shaft Length | 0.109 INCHES MINIMUM AND 0.141 INCHES MAXIMUM |
AEDX | Shaft Style | ROUND, SLOTTED |
APXH | Terminal Location | RIGHT ADJACENT SIDE SINGLE ROW |
ABJT | Terminal Length | 0.578 INCHES MINIMUM AND 0.610 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 3 PIN |