Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
0371S1-100K | 3 - Design Control Reference | 2 - Production Item | EATON AEROSPACE | 08199 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 009021838 | X | A | N | A | A | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
NSN Center Does Not Have An Explanation
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 1 | 1 | TX | 0 | 5 Jun 2000 | 5905014622640 | 5 Jun 2000 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
96 | |||||||||||||||
DLIS-LFF, Battle Creek, MI 49037-3084
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AEFH | Effective Electrical Rotation In Deg Angular Rotation | 16200.0 NOMINAL |
CQCC | Electrical Resistance Per Section | 100.0 KILOHMS SINGLE SECTION |
CRSX | Actuator Travel Control Feature | CLUTCH |
AEFD | Actuator Type | SINGLE SHAFT |
CSDH | Ambient Temp In Deg Celsius Per Section At Full Rated Power | 50.0 SINGLE SECTION |
CQGN | Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 150.0 SINGLE SECTION |
ADAU | Body Height | 0.375 INCHES NOMINAL |
ADAQ | Body Length | 1.250 INCHES NOMINAL |
ADAT | Body Width | 0.250 INCHES NOMINAL |
AAQL | Body Style | RECTANGULAR W/MOUNTING HOLES/SLOTS |
AKPV | Mounting Facility Quantity | 2 |
ABTB | Mounting Hole Diameter | 0.086 INCHES NOMINAL |
AXGY | Mounting Method | UNTHREADED HOLE |
AGTP | Lateral Distance Between Mounting Hole Centers | 1.000 INCHES NOMINAL |
CRGD | Power Dissipation Rating Per Section In Watts | 2.0 FREE AIR SINGLE SECTION |
AARG | Reliability Indicator | NOT ESTABLISHED |
CRSS | Resistance Tolerance Per Section In Percent | -5.0 TO 5.0 SINGLE SECTION |
CQCK | Rotary Actuator Travel In Angular Deg | 16200.0 NOMINAL |
AAPN | Section Quantity | 1 |
ABWV | Shaft Diameter | 0.125 INCHES NOMINAL |
ABXF | Shaft Length | 0.063 INCHES NOMINAL |
AEDX | Shaft Style | ROUND, SLOTTED |
CRFJ | Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius | -50.0 TO 50.0 SINGLE SECTION |
APXH | Terminal Location | LOWER ADJACENT SIDE SINGLE ROW |
TTQY | Terminal Type And Quantity | 3 TAB, SOLDER LUG |