| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| DC1400J39000F | 3 - Design Control Reference | 2 - Production Item | VISHAY DALE ELECTRONICS, INC. | 91637 | |
| 1-128182-3901 | 5 - Replaced / Discontinued | 2 - Production Item | GOULD INSTRUMENT SYSTEMS INC | 96795 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5905 | 009856376 | A001A0 | 05311 | X | 4 | 9 | A | N | U | 1 Jan 1960 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| G900 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
| ZG01 | 1 Jan 2002 | |||||||||||||||||||||||||||||
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 3 | TX | 0 | B | TX | 0 | 21 Jan 1992 | 5905002594627 | 3 Dec 1972 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPP | Electrical Resistance | 3.900 KILOHMS |
| AAQF | Ambient Temp In Deg Celsius At Full Rated Power | 70.0 |
| AAQG | Ambient Temp In Deg Celsius At Zero Percent Rated Power | 165.0 |
| ABPM | Body Diameter | 0.109 INCHES NOMINAL |
| ADAQ | Body Length | 0.468 INCHES NOMINAL |
| AAQZ | Inclosure Method | ENCAPSULATED |
| AEFB | Power Dissipation Rating In Watts | 0.250 FREE AIR |
| AAPQ | Resistance Tolerance In Percent | -1.000/+1.000 |
| STYL | Style Designator | AXIAL TERMINAL EACH END |
| AAQH | Temp Range Of Temp Coefficient In Deg Celsius | -55.0/+165.0 |
| AAPE | Temp Coefficient Of Resistance In Ppm Per Deg Celsius | -500.0/+500.0 |
| AARB | Terminal Type | WIRE LEAD |