Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
232215146801 | 3 - Design Control Reference | 9 - No Longer Used | COMMUNICATION SYSTEMS DIV | 52361 | ![]() |
232215146801 | 3 - Design Control Reference | 9 - No Longer Used | COMMUNICATION SYSTEMS DIV | 52361 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5905 | 010896585 | A001A0 | 05311 | X | 1 | A | N | A | 0 | 5 Feb 1980 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 9 | 5 | TX | D | 232215146801 | 52361 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 6 | B | TX | 0 | 19 May 1992 | 5905011370094 | 17 Oct 1980 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 658 | Z | 9 | A | H | Z | P | 062960 | X | 35140 | REOSTATS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 680.000 OHMS |
AAQF | Ambient Temp In Deg Celsius At Full Rated Power | 70.0 |
AAQG | Ambient Temp In Deg Celsius At Zero Percent Rated Power | 175.0 |
ABPM | Body Diameter | 2.5 MILLIMETERS MAXIMUM |
ADAQ | Body Length | 6.5 MILLIMETERS MAXIMUM |
AAQZ | Inclosure Method | ENCAPSULATED |
AEFB | Power Dissipation Rating In Watts | 0.400 FREE AIR |
AARG | Reliability Indicator | NOT ESTABLISHED |
AAPQ | Resistance Tolerance In Percent | -2.000/+2.000 |
PKWT | Unpackaged Unit Weight | 0.250 GRAMS |
STYL | Style Designator | AXIAL TERMINAL EACH END |
AAPE | Temp Coefficient Of Resistance In Ppm Per Deg Celsius | -100.0/+100.0 |
AAQH | Temp Range Of Temp Coefficient In Deg Celsius | -55.0/+155.0 |
ABJT | Terminal Length | 28.0 MILLIMETERS NOMINAL |
AARB | Terminal Type | WIRE LEAD |