5905-01-216-8524

RESISTOR,VARIABLE,NONWIRE WOUND,NONPRECISION


5905-01-216-8524 (5905012168524, 012168524)
Part Number (1 listing): 62-1-2-203
Summary

FSG 59 / FSC 5905

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 17 Sep 1985

Replacement NSN:

5905-00-401-7415

Replacement Date: 11 Oct 1988

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5905-01-216-8524 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
62-1-2-2033 - Design Control Reference2 - Production ItemVISHAY THIN FILM, LLC  02111    CAGE 02111  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5905-01-216-8524 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595905012168524XANAU17 Sep 1985
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5905

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Resistors

012168524

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5905-01-216-8524

17 Sep 1985

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Type of Item Identification (TYP_II_4820)


NSN Center Does Not Have An Explanation

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5905-01-216-8524 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5905-01-216-8524 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX62-1-2-203  02111   CAGE/02111
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5905-01-216-8524 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX011 Oct 1988 5905004017415 31 Dec 1991
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Oct 1988

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5905-00-401-7415

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

31 Dec 1991

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5905-01-216-8524 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
96
Code Definitions

96

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-LFF, Battle Creek, MI 49037-3084

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5905-01-216-8524 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAPNSection Quantity1
CQCCElectrical Resistance Per Section20.0 KILOHMS SINGLE SECTION
CRSSResistance Tolerance Per Section In Percent-10.0 TO 10.0 SINGLE SECTION
CSDLStandard Taper Curve Per SectionA SINGLE SECTION
AEFMMaximum Stop Torque6.00 INCH-OUNCES
AEFKMaximum Starting Torque5.00 INCH-OUNCES
AEFLMaximum Running Torque5.00 INCH-OUNCES
CRFJTemp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius-100.0 TO 100.0 SINGLE SECTION
CRGDPower Dissipation Rating Per Section In Watts0.75 FREE AIR SINGLE SECTION
CSDHAmbient Temp In Deg Celsius Per Section At Full Rated Power70.0 SINGLE SECTION
CQGNAmbient Temp In Deg Celsius Per Section At Zero Percent Rated Power125.0 SINGLE SECTION
AAQLBody StyleCYLINDRICAL
ABPMBody Diameter0.250 INCHES NOMINAL
ADAQBody Length0.180 INCHES NOMINAL
AEFDActuator TypeFLUSH DRIVE WITH SLOT-HOLE
CQCKRotary Actuator Travel In Angular Deg270.0 NOMINAL
CRSXActuator Travel Control FeatureSTOPS
AEFHEffective Electrical Rotation In Deg Angular Rotation215.0 MINIMUM
AEFNNonturn Device LocationAT 12 OCLOCK
AEFPNonturn Device Radius0.125 INCHES NOMINAL
AXGYMounting MethodTERMINAL
TTQYTerminal Type And Quantity3 PIN
AEHTCenter To Center Distance Between Terminals0.100 INCHES NOMINAL
CQCMCenter To Center Distance Between Center Terminal And Outside Terminal0.100 INCHES NOMINAL
ABJTTerminal Length0.312 INCHES MINIMUM
APXHTerminal LocationREAR END
AARGReliability IndicatorNOT ESTABLISHED
FEATSpecial FeaturesSEALED TO PERMIT CLEANING IN COMMON SOLVENTS


Back to Top