Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
600D271 | 3 - Design Control Reference | 2 - Production Item | SPRAGUE ELECTRIC CO | 56289 | ![]() |
0N171019 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 000040304 | A010B0 | 00008 | X | K | A | P | U | 24 May 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
S019 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
N9BN | N9ND | 3 | C | Z | HD | HD | JB | 1 Jun 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 2 | XN | D | 600D271 | 56289 | ![]() | ||||
3 | 7 | 2 | 2 | XN | D | 0N171019 | 98230 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
0 | TX | 0 | 1 Feb 1975 |
Items under the specification control of Defense Threat Reduction Agency (DTRA) or National Security Agency (NSA).
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XN | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AECQ | Electrical Polarization | POLARIZED |
AECE | Anode Type | ETCHED FOIL |
ABPM | Body Diameter | 0.359 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
ADAQ | Body Length | 1.437 INCHES MAXIMUM |
AAQL | Body Style | W/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS |
CWNJ | Capacitive Electrode Material | ALUMINUM |
CQBQ | Capacitance Value Per Section | 13.000 MICROFARADS SINGLE SECTION |
CWSZ | Case Insulation Material | PLASTIC |
CWJK | Case Material | METAL |
CWQH | Dc Leakage At Reference Temp | 9.000 MICROAMPERES |
CWPM | Dissipation Factor At Reference Temp In Percent | 6.0000 |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 200.0 DC SINGLE SECTION |
AARG | Reliability Indicator | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
ABJT | Terminal Length | 1.875 INCHES MINIMUM AND 1.875 INCHES MINIMUM AND 1.875 INCHES MINIMUM AND 2.125 INCHES MAXIMUM2.125 INCHES MAXIMUM2.125 INCHES MAXIMUM |
CWSG | Terminal Surface Treatment | COPPER |
TTQY | Terminal Type And Quantity | 2 INSULATED WIRE LEAD |
CRTP | Tolerance Range Per Section | -10.00/+50.00 PERCENT SINGLE SECTION |