Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
C 00031 | 3 - Design Control Reference | 9 - No Longer Used | SCIENTIFIC RADIO SYSTEMS INC | 34764 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 000063118 | A010B0 | 00007 | X | 1 | A | P | A | 21 Jun 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 6 | XG | C 00031 | 34764 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USCG Engineering Logistics Center, Baltimore, MD 21226-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XG |
USCG Engineering Logistics Center, Baltimore, MD 21226-5000
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABPM | Body Diameter | 0.920 INCHES NOMINAL |
ADAQ | Body Length | 0.250 INCHES NOMINAL |
AAQL | Body Style | W/O MTG FACILITIES, RADIAL TERMINALS |
CQBQ | Capacitance Value Per Section | 20.000 PICOFARADS SINGLE SECTION |
CWJK | Case Material | PLASTIC |
AEBS | Center To Center Distance Between Terminals Parallel To Diameter | 0.500 INCHES NOMINAL |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 6000.0 DC SINGLE SECTION |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLZ | Temp Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius | 0.0 SINGLE SECTION |
CWPK | Insulation Resistance At Reference Temp | 50000.0 MEGOHMS |
AARG | Reliability Indicator | NOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
ABJT | Terminal Length | 1.500 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |
CRHD | Tolerance Of Temp Coefficient Per Section In Ppm Per Deg Celsius | -30.0 TO 30.0 SINGLE SECTION |
CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |