Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
M39003/01-2988 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-C-39003/1 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
T110A335K015AS | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | KEMET ELECTRONICS CORPORATION | 31433 | ![]() |
11-00480-268 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | RAYTHEON COMPANY | 00724 | ![]() |
2413352B | 5 - Replaced / Discontinued | 2 - Production Item | QES LTD QUALITY ELECTRONIC | KA042 | ![]() |
2414764B | 5 - Replaced / Discontinued | 2 - Production Item | QES LTD QUALITY ELECTRONIC | KA042 | ![]() |
B95057-A2268-B100 | 5 - Replaced / Discontinued | 2 - Production Item | EPCOS AG | C4751 | ![]() |
M39003/01-2989 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003101-2268 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003/1-2268 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003-01-2269 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003-01-2749 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003-01-0140 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003/01-2268 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003/01-2508 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
M39003/01-2748 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
CSR13C335KM | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
CSR13D335K | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
CSR13D335KR | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
CSR13D335KS | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
CSR13D335MR | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
5910000108159 | 5 - Replaced / Discontinued | 9 - No Longer Used | E.C.A ETABLISSEMENT | SCY13 | ![]() |
B95057-A2268-B100 | 5 - Replaced / Discontinued | 9 - No Longer Used | EPCOS AG ABT. PR ROE K PM | D1180 | ![]() |
000-8003-805 | C - Advisory Reference | 1 - Incomplete Part Number | BOEING COMPANY, THE | 94756 | ![]() |
0180-2690 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | ![]() |
947350-2988 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
947350-2988 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
432632 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON TECHNICAL SERVICES COMPANY | 36378 | ![]() |
432632 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON TECHNICAL SERVICES COMPANY | 36378 | ![]() |
6090-0003 | C - Advisory Reference | 1 - Incomplete Part Number | KIDDE-FENWAL INC | 0KDP7 | ![]() |
184-9056-000 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | ![]() |
184-9086-280 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | ![]() |
184-6329-330 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | ![]() |
184-6329-330 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | ![]() |
418356-2268 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 96214 | ![]() |
815-1853037 PIECE 3L | C - Advisory Reference | 1 - Incomplete Part Number | NAVAL SHIP SYSTEMS COMMAND | 80064 | ![]() |
815-1853037 PIECE 3L | C - Advisory Reference | 1 - Incomplete Part Number | NAVAL SHIP SYSTEMS COMMAND | 80064 | ![]() |
336-12-33003 | C - Advisory Reference | 1 - Incomplete Part Number | L-3 COMMUNICATIONS CORPORATION | 06141 | ![]() |
83243-335E6 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN SYSTEMS CORPORATION | 15280 | ![]() |
182808 | C - Advisory Reference | 1 - Incomplete Part Number | FLUKE CORPORATION | 89536 | ![]() |
182808 | C - Advisory Reference | 1 - Incomplete Part Number | FLUKE CORPORATION | 89536 | ![]() |
211-800001-000 | C - Advisory Reference | 1 - Incomplete Part Number | CMC ELECTRONIQUE INC | 90073 | ![]() |
211-800001-000 | C - Advisory Reference | 1 - Incomplete Part Number | CMC ELECTRONIQUE INC | 90073 | ![]() |
222038-000 | C - Advisory Reference | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 81413 | ![]() |
200325-268 | C - Advisory Reference | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 81413 | ![]() |
6320-0005 | C - Advisory Reference | 1 - Incomplete Part Number | KIDDE TECHNOLOGIES INC | 61423 | ![]() |
150D3R3X9015A2 | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | ![]() |
150D3R3X9015A2 | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | ![]() |
150D335X0015A2DYS | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | ![]() |
150D335X0015A2DYS | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | ![]() |
150D335X9010 | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | ![]() |
K3R3J6S | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP MATERIALS SYSTEMS | 05397 | ![]() |
K3R3J6S | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP MATERIALS SYSTEMS | 05397 | ![]() |
K3R3Z15KS | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP MATERIALS SYSTEMS | 05397 | ![]() |
T120B335K015AS | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP MATERIALS SYSTEMS | 05397 | ![]() |
150D335X0015A2 | C - Advisory Reference | 1 - Incomplete Part Number | JOANELL LABORATORIES INC | 04200 | ![]() |
150D335X0015A2 | C - Advisory Reference | 1 - Incomplete Part Number | JOANELL LABORATORIES INC | 04200 | ![]() |
159-25922-04 | C - Advisory Reference | 1 - Incomplete Part Number | GTE COMMUNICATION SYSTEMS CORP | 04773 | ![]() |
0N270686-9 | C - Advisory Reference | 1 - Incomplete Part Number | NATIONAL SECURITY AGENCY | 98230 | ![]() |
0N270686-9 | C - Advisory Reference | 1 - Incomplete Part Number | NATIONAL SECURITY AGENCY | 98230 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 000108159 | A010B0 | 00008 | X | 1 | A | P | A | 0 | 21 Oct 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G170 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G880 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
YW01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZX01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
WI01 | 1 Jun 2001 | |||||||||||||||||||||||||||||
WU01 | 1 Nov 2002 | |||||||||||||||||||||||||||||
WP01 | 1 Dec 2003 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
A918 | A196 | 1 | T | Z | CD | BD | CL | CT | 1 Aug 2006 | |||||||||||||||||||||
DGXT | DTX2 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
MC49 | MC13 | 1 | T | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | T | Z | GH | GT | HD | HS | JB | JV | 1 Aug 2006 | |||||||||||||||||||
S911 | S007 | 1 | T | Z | XN | 1 Aug 2006 | ||||||||||||||||||||||||
YP01 | 1 Nov 2008 | |||||||||||||||||||||||||||||
YA01 | 1 Nov 2008 | |||||||||||||||||||||||||||||
YK01 | 1 Jan 2015 | |||||||||||||||||||||||||||||
YS01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Navy ICP, Mechanicsburg, PA 17055-0788
Naval ICP, Mechanicsburg, PA 17055-0788
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 2 | 2 | E | TX | D | 1 | M39003/01-2988 | 81349 | ![]() | |||
4 | 1 | E | TX | MIL-C-39003/1 | 81349 | ![]() | ||||||
5 | 1 | 2 | ZZ | T110A335K015AS | 31433 | ![]() | ||||||
4 | 5 | 1 | 6 | 9Z | D | 11-00480-268 | 00724 | ![]() | ||||
5 | 2 | 2 | ZG | D | B95057-A2268-B100 | C4751 | ![]() | |||||
5 | 2 | 6 | 9Z | D | 2413352B | KA042 | ![]() | |||||
5 | 2 | 2 | ZK | 2414764B | KA042 | ![]() | ||||||
4 | 5 | 9 | 9 | YP | B | 5910000108159 | SCY13 | ![]() | ||||
4 | 5 | 9 | 2 | ZG | D | B95057-A2268-B100 | D1180 | ![]() | ||||
5 | 9 | 3 | TX | B | CSR13C335KM | 81349 | ![]() | |||||
5 | 9 | 5 | 9Z | B | CSR13D335K | 81349 | ![]() | |||||
4 | 5 | 9 | 3 | TU | B | CSR13D335KR | 81349 | ![]() | ||||
5 | 9 | 3 | TX | B | CSR13D335KS | 81349 | ![]() | |||||
4 | 5 | 9 | 3 | TX | B | CSR13D335MR | 81349 | ![]() | ||||
1 | 5 | 9 | 4 | 9Z | B | M39003-01-0140 | 81349 | ![]() | ||||
4 | 5 | 9 | 3 | TU | B | M39003-01-2269 | 81349 | ![]() | ||||
1 | 5 | 9 | 3 | TU | B | M39003-01-2749 | 81349 | ![]() | ||||
4 | 5 | 9 | 3 | TX | B | M39003/01-2268 | 81349 | ![]() | ||||
5 | 9 | E | TX | B | M39003/01-2508 | 81349 | ![]() | |||||
5 | 9 | E | TU | B | M39003/01-2748 | 81349 | ![]() | |||||
5 | 9 | E | TX | B | M39003/01-2989 | 81349 | ![]() | |||||
5 | 9 | 3 | TX | B | M39003/1-2268 | 81349 | ![]() | |||||
5 | 9 | 3 | TX | B | M39003101-2268 | 81349 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AW | 432632 | 36378 | ![]() | |||
4 | C | 1 | 3 | TX | D | A5 | 150D335X0015A2DYS | 56289 | ![]() | |||
4 | C | 1 | 3 | TU | D | 150D335X9010 | 56289 | ![]() | ||||
4 | C | 1 | 5 | TX | D | AW | 150D3R3X9015A2 | 56289 | ![]() | |||
C | 1 | 5 | TX | AF | 6320-0005 | 61423 | ![]() | |||||
C | 1 | 5 | TX | A5 | 815-1853037 PIECE 3L | 80064 | ![]() | |||||
C | 1 | 5 | TX | AF | 200325-268 | 81413 | ![]() | |||||
C | 1 | 5 | TX | AF | 222038-000 | 81413 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AW | 182808 | 89536 | ![]() | |||
4 | C | 1 | 1 | TX | D | AO | 211-800001-000 | 90073 | ![]() | |||
C | 1 | 5 | TX | AF | 000-8003-805 | 94756 | ![]() | |||||
C | 1 | 5 | TX | AF | 418356-2268 | 96214 | ![]() | |||||
C | 1 | 5 | TX | AW | 0N270686-9 | 98230 | ![]() | |||||
C | 1 | 5 | TX | AW | 150D335X0015A2 | 04200 | ![]() | |||||
C | 1 | 5 | 48 | AH | 159-25922-04 | 04773 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AW | K3R3J6S | 05397 | ![]() | |||
C | 1 | 5 | TX | AF | K3R3Z15KS | 05397 | ![]() | |||||
C | 1 | 6 | TX | AF | T120B335K015AS | 05397 | ![]() | |||||
1 | C | 1 | 5 | 48 | B | 336-12-33003 | 06141 | ![]() | ||||
C | 1 | 6 | TX | AW | 947350-2988 | 06481 | ![]() | |||||
C | 1 | 5 | TX | AF | 6090-0003 | 0KDP7 | ![]() | |||||
4 | C | 1 | 1 | TX | D | BB | 184-6329-330 | 13499 | ![]() | |||
C | 1 | 5 | TX | AF | 184-9056-000 | 13499 | ![]() | |||||
C | 1 | 5 | TX | AF | 184-9086-280 | 13499 | ![]() | |||||
C | 1 | 5 | TX | AF | 83243-335E6 | 15280 | ![]() | |||||
C | 1 | 2 | SB | AB | 0180-2690 | 28480 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
USA
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
Germany
United Kingdom
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is of the type for which an indication of document availability is not required.
Morocco
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Air Force / Defense Logistics Agency
Navy / Defense Logistics Agency
Defense Logistics Agency
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Army / Defense Logistics Agency
Federal Aviation Administration, Oklahoma City, OK 73125
Federal Aviation Administration
Marine Corps / Defense Logistics Agency
645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603
Air Force
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
E | TX | 0 | B | TX | 0 | 4 Feb 1992 | 5910012300399 | 17 Nov 1990 |
An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Department of the Army
Department of the Navy
U.S. Marine Corps
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.1 lbs | 0.002 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | 00 | 0 | A1 | D3 | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
No requirement
Not Applicable
Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AECQ | Electrical Polarization | POLARIZED |
AECE | Anode Type | SOLID |
ABPM | Body Diameter | 0.135 INCHES NOMINAL |
ADAQ | Body Length | 0.286 INCHES NOMINAL |
AAQL | Body Style | W/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS |
CWNJ | Capacitive Electrode Material | TANTALUM |
CQBQ | Capacitance Value Per Section | 3.300 MICROFARADS SINGLE SECTION |
CWSZ | Case Insulation Material | PLASTIC |
CWJK | Case Material | METAL |
CQLH | Dc Leakage At Maximum Operating Temp | 8.0 MICROAMPERES |
CWQH | Dc Leakage At Reference Temp | 0.400 MICROAMPERES |
CWPM | Dissipation Factor At Reference Temp In Percent | 4.000 |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
AARF | Mil-Std-1276 Wire Lead Type Designator | N-3N-3N-3 |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 15.0 DC SINGLE SECTION |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
AARH | Reliability Failure Rate Level In Percent | 0.0010.0010.001 |
AARG | Reliability Indicator | ESTABLISHEDESTABLISHEDESTABLISHED |
AEBZ | Schematic Diagram Designator | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
ZZZK | Specification/Standard Data | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
AEBT | Terminal Diameter | 0.020 INCHES NOMINAL |
ABJT | Terminal Length | 1.500 INCHES NOMINAL1.500 INCHES NOMINAL1.500 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |
TEST | Test Data Document | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |