5910-00-030-5096

CAPACITOR,FIXED,GLASS DIELECTRIC


5910-00-030-5096 (5910000305096, 000305096)
Part Number (1 listing): VY20CA102GA
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 24 Oct 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-030-5096 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
VY20CA102GA3 - Design Control Reference2 - Production ItemVITRAMON INC  95275    CAGE 95275  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-030-5096 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910000305096A010B000004X1APU24 Oct 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

000305096

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-030-5096

A010B0

Federal Item Identification Guide (FIIG_4065)

00004

Item Naming Code (INC_4080)

24 Oct 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-030-5096 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G83000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-030-5096 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332475DVY20CA102GA  95275   CAGE/95275
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-030-5096 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX01 Dec 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Dec 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-030-5096 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
83
Code Definitions

83

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Energy, New York, NY 10014

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-030-5096 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length0.812 INCHES MAXIMUM
ADATBody Width0.185 INCHES MAXIMUM
CQBQCapacitance Value Per Section1000.000 PICOFARADS SINGLE SECTION
CWJKCase MaterialCERAMIC
CWPMDissipation Factor At Reference Temp In Percent0.0010
CQJJNonderated Operating TempUNABLE TO DECODE AND 125.0 DEG CELSIUS MAXIMUM
CQLZTemp Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius0.0 SINGLE SECTION
CWSGTerminal Surface TreatmentSOLDER
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
AAQLBody StyleUNABLE TO DECODE
ADAUBody HeightUNABLE TO DECODE
CQBFInsulation Resistance At Maximum Operating TempUNABLE TO DECODE
CRHDTolerance Of Temp Coefficient Per Section In Ppm Per Deg CelsiusUNABLE TO DECODE
CQWMNonderated Continuous Voltage Rating And Type Per SectionUNABLE TO DECODE
CWPKInsulation Resistance At Reference TempUNABLE TO DECODE
FEATSpecial FeaturesUNABLE TO DECODE
ABJTTerminal Length1.125 INCHES MINIMUM
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
CRTPTolerance Range Per Section-2.00 TO 2.00 PERCENT SINGLE SECTION


Back to Top
Back to Top