Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CM05FD391F03 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 000502181 | A010B0 | 00005 | X | 1 | A | P | U | 28 Jul 1989 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 2 | 4 | 9Z | CM05FD391F03 | 81349 |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
E | TX | 1 | B | TX | 0 | 28 Aug 1992 | 5910010589575 | 28 Aug 1992 |
An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.
Defense Supply Center Columbus, Columbus, OH 43218
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
98 |
DLIS-LFF, Battle Creek, MI 49037-3084
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.117 INCHES NOMINAL |
ADAQ | Body Length | 0.435 INCHES NOMINAL |
ADAT | Body Width | 0.400 INCHES MAXIMUM |
CQBQ | Capacitance Value Per Section | 390.000 MICROFARADS SINGLE SECTION |
CWJK | Case Material | PLASTIC |
CWPM | Dissipation Factor At Reference Temp In Percent | 0.0007 |
CQJJ | Nonderated Operating Temp | UNABLE TO DECODE AND 125.0 DEG CELSIUS MAXIMUM |
AARG | Reliability Indicator | NOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
AAQL | Body Style | UNABLE TO DECODE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | UNABLE TO DECODE AND UNABLE TO DECODE |
CRDN | Temp Coefficient Of Capacitance Range Per Section In Ppm Per Deg Celsius | UNABLE TO DECODE |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | UNABLE TO DECODE |
CWPK | Insulation Resistance At Reference Temp | UNABLE TO DECODE |
TTQY | Terminal Type And Quantity | UNABLE TO DECODE |
ABJT | Terminal Length | 1.000 INCHES MINIMUM |
CRTP | Tolerance Range Per Section | -1.00 TO 1.00 PERCENT SINGLE SECTION |