5910-00-062-0846

CAPACITOR,FIXED,PLASTIC DIELECTRIC


5910-00-062-0846 (5910000620846, 000620846)
Part Number (1 listing): 19A115028P12
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 20 Jun 1967

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-062-0846 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
19A115028P123 - Design Control Reference2 - Production ItemGENERAL ELECTRIC CO  08771    CAGE 08771  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-062-0846 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910000620846A010B000006X1APU20 Jun 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

000620846

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-062-0846

A010B0

Federal Item Identification Guide (FIIG_4065)

00006

Item Naming Code (INC_4080)

20 Jun 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-062-0846 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-062-0846 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321TXD19A115028P12  08771   CAGE/08771
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-062-0846 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX021 Jan 1968
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Jan 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-062-0846 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-062-0846 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.300 INCHES MAXIMUM
ADAQBody Length0.800 INCHES MAXIMUM
AAQLBody StyleW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
ADATBody Width0.660 INCHES MAXIMUM
CQBQCapacitance Value Per Section68000.000 PICOFARADS SINGLE SECTION
CWJKCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length0.500 INCHES MINIMUM AND 0.562 INCHES MAXIMUM
CWPMDissipation Factor At Reference Temp In Percent0.5000
CQWMNonderated Continuous Voltage Rating And Type Per Section200.0 DC SINGLE SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CWPKInsulation Resistance At Reference Temp50000.0 MEGOHM-MICROFARADS
AFHWInternal Electrical Connection TypeEXTENDED FOIL
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
AEBTTerminal Diameter0.031 INCHES MINIMUM AND 0.037 INCHES MAXIMUM
ABJTTerminal Length1.000 INCHES MINIMUM
CWSGTerminal Surface TreatmentSOLDER
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
CRTPTolerance Range Per Section-20.00/+20.00 PERCENT SINGLE SECTION