5910-00-067-5918

CAPACITOR,FIXED,CERAMIC DIELECTRIC


5910-00-067-5918 (5910000675918, 000675918)
Part Numbers (8 listings): 845-200-X5W0-503M | 847-232Y5V503Z | 815-200X5U0503M | 7050-100651-503Z | 455519-10 | 11065344-002 | C023F101L473M | TA50000PF |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 5 Jul 1967

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.001 cu ft

Replacement NSN:

5910-00-341-0635

Replacement Date: 30 Mar 1984

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-067-5918 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
845-200-X5W0-503M3 - Design Control Reference2 - Production ItemTUSONIX, INC.  59660    CAGE 59660  
847-232Y5V503ZC - Advisory Reference1 - Incomplete Part NumberTUSONIX, INC.  59660    CAGE 59660  
847-232Y5V503ZC - Advisory Reference1 - Incomplete Part NumberTUSONIX, INC.  59660    CAGE 59660  
815-200X5U0503MC - Advisory Reference1 - Incomplete Part NumberERIE SPECIALTY PRODUCTS INC  72982    CAGE 72982  
7050-100651-503ZC - Advisory Reference1 - Incomplete Part NumberERIE SPECIALTY PRODUCTS INC  72982    CAGE 72982  
455519-10C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  94580    CAGE 94580  
11065344-002C - Advisory Reference1 - Incomplete Part NumberU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
C023F101L473MC - Advisory Reference1 - Incomplete Part NumberCERA-MITE CORP  60705      
C023F101L473MC - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
TA50000PFC - Advisory Reference1 - Incomplete Part NumberRADIO MATERIALS CORP  91418      
815-200X5U0503MC - Advisory Reference1 - Incomplete Part NumberTUSONIX, INC.  59660    CAGE 59660  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-067-5918 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910000675918A010B000007X1APA05 Jul 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

000675918

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-067-5918

A010B0

Federal Item Identification Guide (FIIG_4065)

00007

Item Naming Code (INC_4080)

5 Jul 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-067-5918 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YJ011 Apr 1991
ZC011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZX011 Apr 1991
ZW011 Dec 1995
YA011 Dec 1999
ZF011 Apr 2000
ZU011 Jul 2005
A918A1963ZZCD1 Jun 2006
C911C0073Z1 Jun 2006
FXGXFXTX3ZZSX1 Jun 2006
MC49MC133ZZPA1 Jun 2006
N9BNN9ND3ZZGHGTKEJBHD1 Jun 2006
S911S0073ZZXN1 Jun 2006
WB011 Apr 2007
WP011 Jun 2007
YP011 Sep 2010
ZT011 Nov 2011
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

Z

Acquisition Method Suffix Code (AMSC_2876)


This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

XN

Item Management Coding Activity (IMC_ACTY_2748)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

JBCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-067-5918 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32EZZ845-200-X5W0-503M  59660   CAGE/59660
C15TUAW847-232Y5V503Z  59660   CAGE/59660
C16TXAFC023F101L473M  60705  
C1EZZ1AF7050-100651-503Z  72982   CAGE/72982
C1EZZAF815-200X5U0503M  72982   CAGE/72982
C1EZZAFTA50000PF  91418  
C1AZZAF455519-10  94580   CAGE/94580
C1AZZAF11065344-002  18876   CAGE/18876
C16TXAFC023F101L473M  56289  
C1EZZAF815-200X5U0503M  59660   CAGE/59660
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

1

Reference Number Justification Code (RNJC_2750)


Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-067-5918 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX130 Mar 1984 5910003410635 10 Dec 1983
1TX03TX17 May 1967 5910005421796 10 Dec 1983
1TX03TX130 Mar 1984 5910007402290 10 Dec 1983
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

30 Mar 1984

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

7 May 1967

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-00-341-0635

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5910-00-542-1796

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5910-00-740-2290

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

10 Dec 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-067-5918 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-00-067-5918 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZU1ZEA0
DFSMSZU1NEA0
DMSMSZU1ZEA0
DNSMSZU1EA0
DSSMSZU1NEA0
GPSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-067-5918 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.1 lbs0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000000DOZZQQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-067-5918 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter0.655 INCHES NOMINAL
ADAQBody Length0.172 INCHES NOMINAL
AAQLBody StyleW/O MTG FACILITIES, RADIAL TERMINALS
CQBQCapacitance Value Per Section50000.000 PICOFARADS SINGLE SECTION
CWJKCase MaterialPLASTIC
AEBSCenter To Center Distance Between Terminals Parallel To Diameter0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM
CWPMDissipation Factor At Reference Temp In Percent2.0000
CQWMNonderated Continuous Voltage Rating And Type Per Section200.0 DC SINGLE SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CWPKInsulation Resistance At Reference Temp10000.0 MEGOHMS
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
AEBTTerminal Diameter0.025 INCHES NOMINAL
ABJTTerminal Length1.500 INCHES MINIMUM
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
CWSGTerminal Surface TreatmentSOLDER
CRTPTolerance Range Per Section-20.00/+20.00 PERCENT SINGLE SECTION


Back to Top