Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MVC07320 | 3 - Design Control Reference | 2 - Production Item | MICROELECTRONICS LTD | 2W239 | ![]() |
453134-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON COMPANY | 54X10 | ![]() |
2022 800 00038 | 5 - Replaced / Discontinued | 2 - Production Item | THALES OPTRONIQUE SAS | F6170 | ![]() |
453134-1 | 5 - Replaced / Discontinued | 2 - Production Item | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
453134-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
MVC07320 | 5 - Replaced / Discontinued | 9 - No Longer Used | VISHAY SPRAGUE INC. | 05079 | ![]() |
MT320 | 5 - Replaced / Discontinued | 9 - No Longer Used | MURATA ERIE NORTH AMERICA INC | 51406 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 001137437 | A096A0 | 00721 | Y | 1 | A | P | A | A | 0 | 4 Sep 1968 |
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
FGGX | FGTX | 3 | D | Z | TG | 1 Jun 2006 | ||||||||||||||||||||||||
N9BN | 3 | D | Z | GH | GG | 1 Dec 2013 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | E | TX | MVC07320 | 2W239 | ![]() | ||||||
5 | 2 | 5 | 48 | 453134-1 | 3B150 | ![]() | ||||||
4 | 5 | 2 | 4 | ZF | A | 2022 800 00038 | F6170 | ![]() | ||||
5 | 2 | 5 | ZZ | 453134-1 | 54X10 | ![]() | ||||||
5 | 9 | E | TX | B | MVC07320 | 05079 | ![]() | |||||
3 | 5 | 9 | 5 | 48 | B | 453134-1 | 49956 | ![]() | ||||
5 | 9 | E | TX | B | MT320 | 51406 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Federal Aviation Administration, Oklahoma City, OK 73125
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
France
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 17 Nov 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | 00 | 0 | D3 | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
No requirement
Not Applicable
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTGR | Adjustment Device Drive Type And Quantity | 1 SLOTTED SCREW |
AXGR | Adjustment Device Torque | 0.500 INCH-OUNCES MINIMUM AND 5.000 INCH-OUNCES MAXIMUM |
ADAU | Body Height | 0.109 INCHES MINIMUM AND 0.141 INCHES MAXIMUM |
ADAQ | Body Length | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
ADAT | Body Width | 0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
AAQL | Body Style | ROTARY |
CTGN | Capacitance Range In Picofarads | +3.5 TO 20.0 SINGLE SECTION |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM |
CRTL | Criticality Code Justification | FEAT |
CTGS | Capacitance Drift In Picofarads | 0.50 SINGLE SECTION |
AGAV | End Item Identification | AIRCRAFT, GALAXY C-5 |
AXHR | Mounting Facility Type And Quantity | 4 TERMINAL |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CTGP | Nonderated Voltage Rating And Type | 50.0 DC CONTINUOUS SINGLE SECTION |
AFJN | Fragility Factor | MODERATELY RUGGED |
MATT | Material | CERAMIC CAPACITIVE ELECTRODE |
AXGT | Insulation Dc Resistance At 25 Deg Celsius | 10000.0 MEGOHMS |
AECJ | Quality Factor At 25 Deg Celsius | 500.0 |
AKNA | Inclosure Type | ENCASED |
FEAT | Special Features | WEAPON SYSTEM ESSENTIAL |
AEBC | Temp Coefficient Of Capacitance In Ppm Per Deg Celsius | -250.0 SINGLE SECTION |
AEBT | Terminal Diameter | 0.023 INCHES NOMINAL |
ABJT | Terminal Length | 0.390 INCHES MINIMUM AND 0.422 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 4 PIN |
AEBD | Tolerance Of Temp Coefficient In Ppm Per Deg Celsius | -250.0 TO 250.0 SINGLE SECTION |