5910-00-154-0547

CAPACITOR,FIXED,ELECTROLYTIC


5910-00-154-0547 (5910001540547, 001540547)
Part Numbers (49 listings): M39003/01-3032 | MIL-C-39003/1 | M39003107-2312 | 2414764B | M39003/1-2312 | M39003-1-2313 | M39003/01-2073 | M39003/01-2553 | M39003/01-2793 | M39003/1-3032 | CS13AF470M | CSR13F476K | CSR13F476KS | CSR13F476K2072 | CSR13F476M | CSR13F476MR | CS15BF470K | M39003-01-2312 | M39003-01-2552 | 5910001540547 | 457-5800 | CSR13F476KM | 150D476X9035R3 | TAS47A35S | 806798-1 | S30-1334 | TS4-35-476-10 | ST513D476K035N | CCP21 | 1660-292 | 200325-792 | 850474-7201 | 441-1276-008 | 402-4-98039-004 | 8524009-193 | 10215-0009 | 2088355-0009 | CS13BF476M | 2612504-6 | TAS476K035P0G | 021196-0001 | K47J35S | 184-9083-730 | 691391-016 | 096-1025-00 | 0220-0476 | 101-471152 | 045-001520-305 | 586058-27 |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 19 Jan 1973

Unit Weight: None

Unit Size:

Unit Pack Cube: None

Replacement NSN:

5910-01-233-0730

Replacement Date: 10 Oct 1992

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-154-0547 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M39003/01-30322 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-C-39003/14 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003107-23125 - Replaced / Discontinued2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
2414764B5 - Replaced / Discontinued2 - Production ItemQES LTD QUALITY ELECTRONIC  KA042    CAGE KA042  
M39003/1-23125 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003-1-23135 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003/01-20735 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003/01-25535 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003/01-27935 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003/1-30325 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CS13AF470M5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CSR13F476K5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CSR13F476KS5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CSR13F476K20725 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CSR13F476M5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CSR13F476MR5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
CS15BF470K5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003-01-23125 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M39003-01-25525 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
59100015405475 - Replaced / Discontinued9 - No Longer UsedE.C.A ETABLISSEMENT  SCY13      
457-58006 - Informative Reference9 - No Longer UsedPAEAEESIKUNTA  A486G      
CSR13F476KMC - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
150D476X9035R3C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
150D476X9035R3C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
TAS47A35SC - Advisory Reference1 - Incomplete Part NumberYOSEMITE INVESTMENT INC  37942    CAGE 37942  
806798-1C - Advisory Reference1 - Incomplete Part NumberEXELIS INC.  31550    CAGE 31550  
S30-1334C - Advisory Reference1 - Incomplete Part NumberMILTOPE CORPORATION  54418    CAGE 54418  
S30-1334C - Advisory Reference1 - Incomplete Part NumberMILTOPE CORPORATION  54418    CAGE 54418  
TS4-35-476-10C - Advisory Reference1 - Incomplete Part NumberAVX TANTALUM CORPORATION  17554      
ST513D476K035NC - Advisory Reference1 - Incomplete Part NumberSIEMENS CORP  25088    CAGE 25088  
CCP21C - Advisory Reference1 - Incomplete Part NumberNAUTEL LIMITED  37338      
1660-292C - Advisory Reference1 - Incomplete Part NumberWOODWARD, INC.  31361      
200325-792C - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS INFORMATION AND  81413    CAGE 81413  
850474-7201C - Advisory Reference1 - Incomplete Part NumberDIAMOND ELECTRONICS INC  55819      
441-1276-008C - Advisory Reference1 - Incomplete Part NumberBOEING COMPANY, THE  94756    CAGE 94756  
402-4-98039-004C - Advisory Reference1 - Incomplete Part NumberEATON AEROSPACE LTD  K2523    CAGE K2523  
8524009-193C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  49671    CAGE 49671  
8524009-193C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  49671    CAGE 49671  
10215-0009C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
2088355-0009C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
2088355-0009C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
CS13BF476MC - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS NATIONAL SECURITY  12436    CAGE 12436  
CS13BF476MC - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS NATIONAL SECURITY  12436    CAGE 12436  
2612504-6C - Advisory Reference1 - Incomplete Part NumberALLIANT TECHSYSTEMS OPERATIONS LLC  06424    CAGE 06424  
TAS476K035P0GC - Advisory Reference1 - Incomplete Part NumberGRACE W R AND CO  76149      
021196-0001C - Advisory Reference1 - Incomplete Part NumberTHALES DEFENSE & SECURITY, INC.  65597    CAGE 65597  
K47J35SC - Advisory Reference1 - Incomplete Part NumberAVX LTD  K8295      
184-9083-730C - Advisory Reference1 - Incomplete Part NumberROCKWELL COLLINS, INC.  13499    CAGE 13499  
691391-016C - Advisory Reference1 - Incomplete Part NumberL-3 COMMUNICATIONS CORPORATION  06141    CAGE 06141  
096-1025-00C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  22373    CAGE 22373  
0220-0476C - Advisory Reference1 - Incomplete Part NumberDATUM INC  31160    CAGE 31160  
CCP21C - Advisory Reference1 - Incomplete Part NumberNAUTEL MAINE INC.  57655    CAGE 57655  
CS13AF470MC - Advisory Reference1 - Incomplete Part NumberCALLINS INDUSTRIES INC  05844      
101-471152C - Advisory Reference1 - Incomplete Part NumberALLIED SIGNAL INC  83298    CAGE 83298  
101-471152C - Advisory Reference1 - Incomplete Part NumberALLIED SIGNAL INC  83298    CAGE 83298  
045-001520-305C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  26916    CAGE 26916  
586058-27C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
586058-27C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
850474-7201C - Advisory Reference1 - Incomplete Part NumberGENERAL DYNAMICS ADVANCED  92325      
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6 - Informative Reference

Reference Number Category Code (DRN_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-154-0547 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910001540547A010B000008X1APA019 Jan 1973
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

001540547

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-154-0547

A010B0

Federal Item Identification Guide (FIIG_4065)

00008

Item Naming Code (INC_4080)

19 Jan 1973

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-154-0547 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G07000L1 Apr 1991
G88000C1 Apr 1991
YB011 Apr 1991
YW011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZP011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
YJ011 Apr 1991
ZX011 Apr 1991
ZW011 Nov 1998
WI011 Jun 2001
WB011 Feb 2005
WF011 Nov 2008
YA011 Nov 2008
YP011 Nov 2008
YK011 Jan 2015
YS011 Feb 2015
YF011 May 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-154-0547 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4223TXD1M39003/01-3032  81349   CAGE/81349
41ETXMIL-C-39003/1  81349   CAGE/81349
5269Z12414764B  KA042   CAGE/KA042
5269Z1M39003107-2312  81349   CAGE/81349
4599YPB5910001540547  SCY13  
4593TXBM39003/1-2312  81349   CAGE/81349
59ETXBM39003/1-3032  81349   CAGE/81349
59ETXBCS13AF470M  81349   CAGE/81349
59ETXBCS15BF470K  81349   CAGE/81349
5969ZBCSR13F476K  81349   CAGE/81349
159548BCSR13F476K2072  81349   CAGE/81349
593TXBCSR13F476KS  81349   CAGE/81349
593TXBCSR13F476M  81349   CAGE/81349
4593TXBCSR13F476MR  81349   CAGE/81349
159348BM39003-01-2312  81349   CAGE/81349
4593TXBM39003-01-2552  81349   CAGE/81349
4593TUBM39003-1-2313  81349   CAGE/81349
593TXBM39003/01-2073  81349   CAGE/81349
4593TXBM39003/01-2553  81349   CAGE/81349
4593TXBM39003/01-2793  81349   CAGE/81349
4699WFB457-5800  A486G  
C15TXAF402-4-98039-004  K2523   CAGE/K2523
C15TXAFK47J35S  K8295  
C15TXAF200325-792  81413   CAGE/81413
C1ACLAO101-471152  83298   CAGE/83298
C1548AH850474-7201  92325  
C15TXAF441-1276-008  94756   CAGE/94756
C15TXAFCS13AF470M  05844  
C1548AH691391-016  06141   CAGE/06141
C15TXAF2612504-6  06424   CAGE/06424
4C16TXDAWCS13BF476M  12436   CAGE/12436
3C1548D184-9083-730  13499   CAGE/13499
1C1548BTS4-35-476-10  17554  
1C1548BAH096-1025-00  22373   CAGE/22373
1C1548BAHST513D476K035N  25088   CAGE/25088
C15TXAF045-001520-305  26916   CAGE/26916
1C1548B10215-0009  27914   CAGE/27914
4C15TXDAW2088355-0009  27914   CAGE/27914
1C1548BAH0220-0476  31160   CAGE/31160
4C15TXDAF1660-292  31361  
C1548AH806798-1  31550   CAGE/31550
C1548AHCCP21  37338  
C1448AHTAS47A35S  37942   CAGE/37942
C16TXAW8524009-193  49671   CAGE/49671
4C11TXDA5586058-27  49956   CAGE/49956
4C15TXDAOS30-1334  54418   CAGE/54418
1C1548B850474-7201  55819  
4C13TXDAO150D476X9035R3  56289  
1C1548BCSR13F476KM  56289  
C1548AHCCP21  57655   CAGE/57655
1C1548B021196-0001  65597   CAGE/65597
4C19TUBTAS476K035P0G  76149  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Justification Code (RNJC_2750)


Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

YP

Reference Number Action Activity Code (RNAAC_2900)


Morocco

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

6

Reference Number Category Code (RNCC_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

WF

Reference Number Action Activity Code (RNAAC_2900)


Finland

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

AO

Service / Agency Designator Code (SADC_4672)


Army / Defense Logistics Agency

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

A5

Service / Agency Designator Code (SADC_4672)


Navy / Defense Logistics Agency


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-154-0547 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
ETX0BTX010 Oct 1992 5910012330730 26 Feb 1991
Code Definitions

E

Item Standardization Code (ISC_2650)


An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

10 Oct 1992

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-01-233-0730

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

26 Feb 1991

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-154-0547 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZG658Z9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

ZG

Originating Activity Code (ORIG_ACTY_CD_4210)


Germany

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-00-154-0547 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU1EA0
DAS9EYU1ZEA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-154-0547 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000000A1D1QQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

A1

Unit Container Code (UNIT_CTNR_CD_5166)


Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-154-0547 Submit RFQ
MRCDecoded RequirementClear Text Reply
AECQElectrical PolarizationPOLARIZED
AECEAnode TypeSOLID
ABPMBody Diameter0.351 INCHES NOMINAL
ADAQBody Length0.786 INCHES NOMINAL
AAQLBody StyleW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS
CWNJCapacitive Electrode MaterialTANTALUM
CQBQCapacitance Value Per Section47.000 MICROFARADS SINGLE SECTION
CWSZCase Insulation MaterialPLASTIC
CWJKCase MaterialMETAL
CQLHDc Leakage At Maximum Operating Temp160.0 MICROAMPERES
CWQHDc Leakage At Reference Temp16.000 MICROAMPERES
CWPMDissipation Factor At Reference Temp In Percent6.0000
AARFMil-Std-1276 Wire Lead Type DesignatorN-3N-3N-3
CQWMNonderated Continuous Voltage Rating And Type Per Section35.0 DC SINGLE SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
AARHReliability Failure Rate Level In Percent0.00100.00100.0010
AARGReliability IndicatorESTABLISHEDESTABLISHEDESTABLISHED
AEBZSchematic Diagram DesignatorELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
ZZZKSpecification/Standard Data81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION
AEBTTerminal Diameter0.025 INCHES NOMINAL
ABJTTerminal Length1.500 INCHES NOMINAL1.500 INCHES NOMINAL1.500 INCHES NOMINAL
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
TESTTest Data Document81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
CRTPTolerance Range Per Section-10.00/+10.00 PERCENT SINGLE SECTION


Back to Top
Back to Top