Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3XDMRTWA1-10 | 3 - Design Control Reference | 9 - No Longer Used | SOLAR CAPACITOR SALES CORP | 90177 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 002381375 | A010B0 | 00003 | X | 1 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
YA01 | 1 Jan 2002 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 3 Oct 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 658 | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.000 INCHES NOMINAL |
ADAQ | Body Length | 1.812 INCHES NOMINAL |
AAQL | Body Style | W/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CWJK | Case Material | METAL |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.125 INCHES NOMINAL |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
CQBQ | Capacitance Value Per Section | 0.100 MICROFARADS 1ST SECTION |
CQBQ | Capacitance Value Per Section | 0.100 MICROFARADS 2ND SECTION |
CQBQ | Capacitance Value Per Section | 0.100 MICROFARADS 3RD SECTION |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED MOUNTING HOLES |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 400.0 DC 2ND SECTION |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 400.0 DC 3RD SECTION |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 400.0 DC 1ST SECTION |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
BWGP | Section Quantity | 3 |
AARG | Reliability Indicator | NOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | ELECTRODE(S) GROUNDED TO CASE |
AEBV | Unthreaded Mounting Hole Diameter | 0.188 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 3 TAB, SOLDER LUG |
CRTP | Tolerance Range Per Section | -10.00 TO 10.00 PERCENT 1ST SECTION |
CRTP | Tolerance Range Per Section | -10.00 TO 10.00 PERCENT 2ND SECTION |
CRTP | Tolerance Range Per Section | -10.00 TO 10.00 PERCENT 3RD SECTION |