5910-00-432-6965

CAPACITOR,FIXED,ELECTROLYTIC


5910-00-432-6965 (5910004326965, 004326965)
Part Numbers (14 listings): 16758058-134 | 196D106X9020JA1 | TD1-010-106-10 | 56-12731F106N20 | 196D106X0020KA1 | 196D106X9015JA1 | 196X9015JA1 | 196D106X-00115 | 196D106X0015JA1 | 196D106X0020 | 823-106-41 | 33601002 | ST821B106K015 | 235-7359P23 |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 11 Feb 1972

Unit Weight: None

Unit Size:

Unit Pack Cube: None

Replacement NSN:

5910-00-205-9119

Replacement Date: 19 Apr 1982

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-432-6965 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
16758058-1343 - Design Control Reference2 - Production ItemSYPRIS ELECTRONICS, LLC  28009    CAGE 28009  
196D106X9020JA13 - Design Control Reference2 - Production ItemSPRAGUE ELECTRIC CO  56289      
TD1-010-106-105 - Replaced / Discontinued2 - Production ItemAVX TANTALUM CORPORATION  17554      
56-12731F106N205 - Replaced / Discontinued9 - No Longer UsedDIGITEC CORP  16152    CAGE 16152  
196D106X0020KA15 - Replaced / Discontinued9 - No Longer UsedSPRAGUE ELECTRIC CO  56289      
196D106X9015JA15 - Replaced / Discontinued9 - No Longer UsedSPRAGUE ELECTRIC CO  56289      
196X9015JA1C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
196D106X-00115C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
196D106X-00115C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
196D106X0015JA1C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
196D106X0020C - Advisory Reference1 - Incomplete Part NumberSPRAGUE ELECTRIC CO  56289      
823-106-41C - Advisory Reference1 - Incomplete Part NumberAMETEK PROGRAMMABLE POWER, INC.  25965    CAGE 25965  
33601002C - Advisory Reference1 - Incomplete Part NumberDELTYME CORPORATION  52297      
ST821B106K015C - Advisory Reference1 - Incomplete Part NumberMICROSEMI CORP.-SCOTTSDALE  12954    CAGE 12954  
ST821B106K015C - Advisory Reference1 - Incomplete Part NumberMICROSEMI CORP.-SCOTTSDALE  12954    CAGE 12954  
235-7359P23C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
235-7359P23C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-432-6965 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910004326965A010B000008X1APU11 Feb 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

004326965

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-432-6965

A010B0

Federal Item Identification Guide (FIIG_4065)

00008

Item Naming Code (INC_4080)

11 Feb 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-432-6965 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
ZC011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZT011 Apr 1991
G90000L1 Apr 1991
YB011 Apr 1991
ZW011 Nov 1998
YS011 Feb 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-432-6965 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4321TXD16758058-134  28009   CAGE/28009
3323TXD196D106X9020JA1  56289  
4523TXDTD1-010-106-10  17554  
595TXB56-12731F106N20  16152   CAGE/16152
595TXB196D106X0020KA1  56289  
4593TUB196D106X9015JA1  56289  
4C19TUB196X9015JA1  56289  
C16TXAWST821B106K015  12954   CAGE/12954
1C1548B823-106-41  25965   CAGE/25965
C16TXA5235-7359P23  49956   CAGE/49956
1C1548B33601002  52297  
C15SBAW196D106X-00115  56289  
4C13TXD196D106X0015JA1  56289  
4C19TUB196D106X0020  56289  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

A5

Service / Agency Designator Code (SADC_4672)


Navy / Defense Logistics Agency

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-432-6965 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX01TX019 Apr 1982 5910002059119 7 May 1982
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

19 Apr 1982

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-00-205-9119

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

7 May 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-432-6965 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX658Z9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-00-432-6965 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU0EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-432-6965 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APZZXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XQQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-432-6965 Submit RFQ
MRCDecoded RequirementClear Text Reply
AECQElectrical PolarizationPOLARIZED
AECEAnode TypeSOLID
ABPMBody Diameter0.225 INCHES MAXIMUM
ADAQBody Length0.425 INCHES MAXIMUM
AAQLBody StyleW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CWNJCapacitive Electrode MaterialTANTALUM
CQBQCapacitance Value Per Section10.000 MICROFARADS SINGLE SECTION
CWJKCase MaterialPLASTIC
AEBSCenter To Center Distance Between Terminals Parallel To Diameter0.095 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
CWQHDc Leakage At Reference Temp3.000 MICROAMPERES
CWPMDissipation Factor At Reference Temp In Percent8.0000
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CQWMNonderated Continuous Voltage Rating And Type Per Section20.0 DC SINGLE SECTION
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
AEBTTerminal Diameter0.020 INCHES NOMINAL
ABJTTerminal Length0.750 INCHES NOMINAL
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
CWSGTerminal Surface TreatmentSOLDER
CRTPTolerance Range Per Section-10.00/+10.00 PERCENT SINGLE SECTION


Back to Top
Back to Top