Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
300B448 | 1 - Source of Control Reference | 2 - Production Item | INSTRUMENT SYSTEMS CORP | 09966 | ![]() |
5C067334X0101B3 | 3 - Design Control Reference | 2 - Production Item | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5C10 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5C10A7CML | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5351-055 | E - Replace Reference Number | 8 - Replacement NSN | RAYTHEON COMPANY | 05869 | ![]() |
SR832E334MAA | E - Replace Reference Number | 8 - Replacement NSN | AVX CORPORATION | 04222 | ![]() |
0160-0137 | E - Replace Reference Number | 8 - Replacement NSN | AGILENT TECHNOLOGIES, INC. | 1LQK8 | ![]() |
5033ES50RD334M | E - Replace Reference Number | 8 - Replacement NSN | ILLINOIS TOOL WORKS INC | 20932 | ![]() |
0160-0137 | E - Replace Reference Number | 8 - Replacement NSN | HEWLETT PACKARD CO | 28480 | ![]() |
134-147-4 | E - Replace Reference Number | 8 - Replacement NSN | TELEVISONET INC | 17671 | ![]() |
W300-025-601-334M0.375LS | E - Replace Reference Number | 8 - Replacement NSN | CENTRE CAPACITOR INC | 51642 | ![]() |
RPE112-149Z5U334M50V | E - Replace Reference Number | 8 - Replacement NSN | MURATA ERIE NORTH AMERICA INC | 51406 | ![]() |
8151-N026-651-334M8131 | E - Replace Reference Number | 8 - Replacement NSN | ERIE SPECIALTY PRODUCTS INC | 72982 | ![]() |
CZ30D334MJ | E - Replace Reference Number | 8 - Replacement NSN | CRL COMPONENTS INC | 71590 | ![]() |
7C023334X0500E | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
7CZ5U334X0050E1 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
2C37Z5U334M050B | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
4C44A | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5CZ5U334X0025C5C-CML | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5C023334D8500C5 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
5C023334X0250B3 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | ![]() |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 004808267 | A010B0 | 00007 | X | 1 | A | P | A | 0 | 18 Sep 1970 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Jan 2002 | |||||||||||||||||||||||||||||
ZR01 | 1 Jan 2008 | |||||||||||||||||||||||||||||
ZU01 | 1 Jan 2008 | |||||||||||||||||||||||||||||
ZH01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
ZP01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
ZC01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
ZF01 | 1 Jan 2009 | |||||||||||||||||||||||||||||
DGX1 | 3 | B | 1 Apr 2012 | |||||||||||||||||||||||||||
YF01 | 1 Oct 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 1 | 2 | 1 | KE | D | 300B448 | 09966 | ![]() | ||||
3 | 3 | 2 | 5 | KE | D | 5C067334X0101B3 | 56289 | ![]() | ||||
1 | E | 8 | 6 | TX | B | 5C10 | 56289 | ![]() | ||||
1 | E | 8 | 6 | TX | B | 5C10A7CML | 56289 | ![]() | ||||
4 | E | 8 | 6 | TX | B | 5CZ5U334X0025C5C-CML | 56289 | ![]() | ||||
E | 8 | 3 | TX | 7C023334X0500E | 56289 | ![]() | ||||||
E | 8 | 3 | TX | 7CZ5U334X0050E1 | 56289 | ![]() | ||||||
4 | E | 8 | 6 | TX | D | CZ30D334MJ | 71590 | ![]() | ||||
4 | E | 8 | 6 | TX | B | 8151-N026-651-334M8131 | 72982 | ![]() | ||||
3 | E | 8 | 6 | ZB | D | 134-147-4 | 17671 | ![]() | ||||
4 | E | 8 | 5 | ZZ | D | 0160-0137 | 1LQK8 | ![]() | ||||
4 | E | 8 | 5 | TX | B | 5033ES50RD334M | 20932 | ![]() | ||||
1 | E | 8 | 1 | TX | B | 0160-0137 | 28480 | ![]() | ||||
4 | E | 8 | 5 | TX | D | RPE112-149Z5U334M50V | 51406 | ![]() | ||||
4 | E | 8 | 5 | TX | D | W300-025-601-334M0.375LS | 51642 | ![]() | ||||
4 | E | 8 | 5 | TX | D | 2C37Z5U334M050B | 56289 | ![]() | ||||
3 | E | 8 | 3 | TX | B | 4C44A | 56289 | ![]() | ||||
3 | E | 8 | 3 | TX | D | 5C023334D8500C5 | 56289 | ![]() | ||||
1 | E | 8 | 3 | TX | D | 5C023334X0250B3 | 56289 | ![]() | ||||
4 | E | 8 | 5 | TX | D | SR832E334MAA | 04222 | ![]() | ||||
3 | E | 8 | 6 | ZB | D | 5351-055 | 05869 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Belgium
USA
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 0 | 30 Mar 1984 | 5910007335688 | 2 Apr 1984 |
1 | TX | 0 | 3 | TX | 1 | 7 May 1967 | 5910008127276 | 2 Apr 1984 |
1 | TX | 0 | 3 | TX | 1 | 30 Mar 1984 | 5910009141165 | 2 Apr 1984 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Naval ICP, Philadelphia, PA 19111
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Department of the Navy
Department of the Army
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | 00 | 0 | D3 | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
No requirement
Not Applicable
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.238 INCHES NOMINAL |
ADAQ | Body Length | 0.500 INCHES NOMINAL |
AAQL | Body Style | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
ADAT | Body Width | 0.500 INCHES NOMINAL |
CQBQ | Capacitance Value Per Section | 330.000 NANOFARADS SINGLE SECTION |
CWJK | Case Material | PLASTIC |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM |
CWPM | Dissipation Factor At Reference Temp In Percent | 2.0000 |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 100.0 DC SINGLE SECTION |
CWPK | Insulation Resistance At Reference Temp | 100000.0 MEGOHMS |
AARG | Reliability Indicator | NOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
CQFB | Voltage Temp Limits Per Section In Percent Capacitance Change | -15.0/+15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
ABJT | Terminal Length | 1.250 INCHES MINIMUM |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |
CWSG | Terminal Surface Treatment | SOLDER |
CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |