5910-00-519-8557

CAPACITOR,VARIABLE,AIR DIELECTRIC


5910-00-519-8557 (5910005198557, 005198557)
Part Numbers (5 listings): 160-205-99 | 5MB11 | 10051943 | 160-205 | 647-805012 |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1961

Unit Weight: 0.3 lbs

Unit Size: None

Unit Pack Cube: 0.017 cu ft

Replacement NSN:

5910-00-668-9375

Replacement Date: 3 Nov 1973

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-519-8557 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
160-205-993 - Design Control Reference1 - Incomplete Part NumberVIKING TECHNOLOGIES, LTD.  71313    CAGE 71313  
5MB113 - Design Control Reference1 - Incomplete Part NumberVIKING TECHNOLOGIES, LTD.  71313    CAGE 71313  
100519433 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
5MB115 - Replaced / Discontinued9 - No Longer UsedVIKING TECHNOLOGIES, LTD.  74970    CAGE 74970  
160-2055 - Replaced / Discontinued9 - No Longer UsedVIKING TECHNOLOGIES, LTD.  74970    CAGE 74970  
647-805012E - Replace Reference Number8 - Replacement NSNVIASYS RESPIRATORY CARE INC.  53110    CAGE 53110  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E - Replace Reference Number

Reference Number Category Code (DRN_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

8 - Replacement NSN

Reference Number Variation Code (DRN_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-519-8557 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910005198557A096A000531X1APA01 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

005198557

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-519-8557

A096A0

Federal Item Identification Guide (FIIG_4065)

00531

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-519-8557 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
ZU011 Apr 1991
ZW011 Nov 1998
A918A1963LZCDCL1 Jun 2006
FXGXFXTX3LZSX1 Jun 2006
MC49MC133LZPA1 Jun 2006
N9BNN9ND3LZGHHDKE1 Jun 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

L

Acquisition Method Suffix Code (AMSC_2876)


The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-519-8557 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4311TXD160-205-99  71313   CAGE/71313
316TX5MB11  71313   CAGE/71313
4321TXD10051943  18876   CAGE/18876
4593TXB160-205  74970   CAGE/74970
4596TXB5MB11  74970   CAGE/74970
E85TX647-805012  53110   CAGE/53110
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

E

Reference Number Category Code (RNCC_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

8

Reference Number Variation Code (RNVC_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-519-8557 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX13 Nov 1973 5910006689375 6 May 1969
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

3 Nov 1973

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-00-668-9375

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

6 May 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-519-8557 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
723Z9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-00-519-8557 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSJU1ZEA0
DFSMSJU1NEA0
DMSMSJU1ZEA0
DNSMSJU1EA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-519-8557 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP511AAA0.3 lbs0.017 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FADAXD1DOZZQQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

51

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.3 lbs

Unit Pack Weight (UP_WT_5153)

0.017 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

DA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


A-A-1051, paperboard cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-519-8557 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTGRAdjustment Device Drive Type And Quantity1 SHAFT
AXGJAdjustment Device Rotation180.0 DEGREES NOMINAL CLOCKWISE AND 180.0 DEGREES NOMINAL COUNTERCLOCKWISE
AXGRAdjustment Device Torque1.500 INCH-OUNCES MINIMUM AND 6.000 INCH-OUNCES MAXIMUM
ADAQBody Length0.812 INCHES NOMINAL
AAQLBody StylePLATE-MESHING
ABKHBushing Diameter0.250 INCHES NOMINAL
ABXDBushing Length0.562 INCHES NOMINAL
AXGSBushing ShapeROUND W/DOUBLE FLAT
AXHGBushing Width0.187 INCHES NOMINAL
CTGNCapacitance Range In Picofarads+1.8/+5.1 ALL SECTIONS
AKEJMounting Facility Screw Thread Series DesignatorUNEF
AXHRMounting Facility Type And Quantity1 THREADED BUSHING
CQJXNominal Thread Size0.250 INCHES
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 175.0 DEG CELSIUS MAXIMUM
CTGPNonderated Voltage Rating And Type1250.0 AC PEAK ALL SECTIONS
AFBHIndividual Section Quantity2
AKNAInclosure TypeUNINCLOSED
AXGTInsulation Dc Resistance At 25 Deg Celsius10.0 GIGOHMS
ABWVShaft Diameter0.188 INCHES NOMINAL SINGLE SHAFT
ABXFShaft Length0.500 INCHES NOMINAL SINGLE SHAFT
CRSJShaft TypeROUND, SLOTTED SINGLE SHAFT
ABKWOverall Height0.750 INCHES NOMINAL
ABHPOverall Length1.312 INCHES NOMINAL
ABMKOverall Width0.625 INCHES NOMINAL
AEBDTolerance Of Temp Coefficient In Ppm Per Deg Celsius-150.0/+150.0 ALL SECTIONS
AXCMTuning CharacteristicSTRAIGHT LINE CAPACITY ALL SECTIONS
AXCNSplit-Stator Rotary Plate TypeBUTTERFLY
AEBCTemp Coefficient Of Capacitance In Ppm Per Deg Celsius50.0 ALL SECTIONS
TTQYTerminal Type And Quantity3 TAB, SOLDER LUG
AAJDThread Class2A


Back to Top
Back to Top