5910-00-649-1807

CAPACITOR,FIXED,PAPER DIELECTRIC


5910-00-649-1807 (5910006491807, 006491807)
Part Number (1 listing): Z1885Y
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-649-1807 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
Z1885Y3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  77342    CAGE 77342  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-649-1807 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910006491807A010B000003XKAPU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

006491807

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-649-1807

A010B0

Federal Item Identification Guide (FIIG_4065)

00003

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-649-1807 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-649-1807 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CTX06 Sep 1971
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Sep 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-649-1807 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P658Z9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-649-1807 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.875 INCHES NOMINAL
ADAQBody Length1.750 INCHES NOMINAL
AAQLBody StyleW/MTG TABS/FLANGES TERMINALS ON OPPOSITE SURFACES
ADATBody Width1.250 INCHES NOMINAL
CWJKCase MaterialMETAL
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length2.125 INCHES NOMINAL
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
CQBQCapacitance Value Per Section0.100 MICROFARADS 4TH SECTION
CQBQCapacitance Value Per Section0.100 MICROFARADS 1ST SECTION
CQBQCapacitance Value Per Section0.100 MICROFARADS 2ND SECTION
CQBQCapacitance Value Per Section0.100 MICROFARADS 3RD SECTION
AXHRMounting Facility Type And Quantity2 UNTHREADED MOUNTING HOLES
CQWMNonderated Continuous Voltage Rating And Type Per Section125.0 AC-RMS 1ST SECTION
CQWMNonderated Continuous Voltage Rating And Type Per Section125.0 AC-RMS 2ND SECTION
CQWMNonderated Continuous Voltage Rating And Type Per Section125.0 AC-RMS 3RD SECTION
CQWMNonderated Continuous Voltage Rating And Type Per Section125.0 AC-RMS 4TH SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BWGPSection Quantity4
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorELECTRODE(S) GROUNDED TO CASE
CRTPTolerance Range Per Section-10.00 TO 25.00 PERCENT 1ST SECTION
CRTPTolerance Range Per Section-10.00 TO 25.00 PERCENT 2ND SECTION
CRTPTolerance Range Per Section-10.00 TO 25.00 PERCENT 3RD SECTION
CRTPTolerance Range Per Section-10.00 TO 25.00 PERCENT 4TH SECTION
AEBVUnthreaded Mounting Hole Diameter0.170 INCHES NOMINAL
TTQYTerminal Type And Quantity4 INSULATED WIRE LEAD W/TERMINAL LUG


Back to Top