5910-00-666-7498

CAPACITOR,FIXED,PAPER DIELECTRIC


5910-00-666-7498 (5910006667498, 006667498)
Part Number (1 listing): 86P47403S5
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5910-01-011-1733

Replacement Date: 16 Sep 1976

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-666-7498 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
86P47403S53 - Design Control Reference9 - No Longer UsedCRL COMPONENTS INC  71590    CAGE 71590  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-666-7498 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910006667498A010B000003X1APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

006667498

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-666-7498

A010B0

Federal Item Identification Guide (FIIG_4065)

00003

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-666-7498 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZH011 Apr 1991
ZU011 Apr 1991
WB011 Feb 2005
ZW011 Nov 2005
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-666-7498 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX0BTX016 Sep 1976 5910010111733 3 Feb 1969
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

16 Sep 1976

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-01-011-1733

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

3 Feb 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-666-7498 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-666-7498 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00FA000A1D100QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

FA

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-P-130, laminated and creped wrapping paper

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

A1

Unit Container Code (UNIT_CTNR_CD_5166)


Bags made of material conforming to MIL-P-130, MIL-DTL-17667, MIL-PRF-121, or any material authorized by MIL-DTL-117. Closure may be by staples, tape, adhesive or heat seal.

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-666-7498 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter0.562 INCHES NOMINAL
ADAUBody Height0.562 INCHES NOMINAL
ADAQBody Length1.812 INCHES NOMINAL
AAQLBody StyleW/THD BUSHING MTG, TERMINAL(S) ON ONE END
ADATBody Width0.562 INCHES NOMINAL
CWJKCase MaterialMETAL
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
CQBQCapacitance Value Per Section0.470 MICROFARADS SINGLE SECTION
AXHRMounting Facility Type And Quantity1 THREADED BUSHING
CQJXNominal Thread Size0.312 INCHES
CQWMNonderated Continuous Voltage Rating And Type Per Section300.0 DC SINGLE SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
AKEJMounting Facility Screw Thread Series DesignatorUNF
CWSGTerminal Surface TreatmentSOLDER
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
CRTPTolerance Range Per Section-20.00 TO 20.00 PERCENT SINGLE SECTION
ABJTTerminal Length0.281 INCHES NOMINAL
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD


Back to Top