5910-00-938-4649

CAPACITOR,FIXED,ELECTROLYTIC


5910-00-938-4649 (5910009384649, 009384649)
Part Numbers (11 listings): T330A156K010AS | K15P10K | T330X156K010AS | SK2106 | SMA595889-6 | TIM156M10P0X | 304959-78 | 310001560 | 275054-361 | T330A156K010AS1 | T330A156M010AS |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 21 Mar 1967

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5910-00-001-7626

Replacement Date: 5 Mar 1982

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-00-938-4649 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
T330A156K010AS3 - Design Control Reference9 - No Longer UsedUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
K15P10K5 - Replaced / Discontinued9 - No Longer UsedUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
T330X156K010AS5 - Replaced / Discontinued9 - No Longer UsedUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
SK21065 - Replaced / Discontinued9 - No Longer UsedUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
SMA595889-6C - Advisory Reference1 - Incomplete Part NumberGENERAL DYNAMICS C4 SYSTEMS, INC.  04655    CAGE 04655  
TIM156M10P0XC - Advisory Reference1 - Incomplete Part NumberMALLORY SONALERT PRODUCTS INC.  90201    CAGE 90201  
SK2106C - Advisory Reference1 - Incomplete Part NumberALLIANT DEFENSE ELECTRONICS SYSTEMS  05714      
304959-78C - Advisory Reference1 - Incomplete Part NumberTRANSICO INC.  97525      
310001560C - Advisory Reference1 - Incomplete Part NumberNORTHERN TELECOM INC  06819      
275054-361C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  37695    CAGE 37695  
T330A156K010AS1C - Advisory Reference1 - Incomplete Part NumberUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
T330A156M010ASC - Advisory Reference1 - Incomplete Part NumberUNION CARBIDE CORP MATERIALS SYSTEMS  05397    CAGE 05397  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5910-00-938-4649 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910009384649A010B000008X1APU21 Mar 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

009384649

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-00-938-4649

A010B0

Federal Item Identification Guide (FIIG_4065)

00008

Item Naming Code (INC_4080)

21 Mar 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5910-00-938-4649 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Nov 1998
A918A1963LZCD1 Jun 2006
N9BNNIND3LZGHHDKE1 Jun 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

L

Acquisition Method Suffix Code (AMSC_2876)


The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-00-938-4649 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3393TXDT330A156K010AS  05397   CAGE/05397
3593TXBK15P10K  05397   CAGE/05397
3591TXDSK2106  05397   CAGE/05397
3593TXDT330X156K010AS  05397   CAGE/05397
C16ZZACSK2106  05714  
C16ZZAC310001560  06819  
C11ZZAC275054-361  37695   CAGE/37695
C16ZZACTIM156M10P0X  90201   CAGE/90201
C16ZZAC304959-78  97525  
C15ZZACT330A156K010AS1  05397   CAGE/05397
1C1548BT330A156M010AS  05397   CAGE/05397
C16ZZACSMA595889-6  04655   CAGE/04655
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-00-938-4649 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX05 Mar 1982 5910000017626 21 Mar 1982
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

5 Mar 1982

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5910-00-001-7626

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

21 Mar 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-00-938-4649 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061400X34450CONDENSERS-PARTS-NOI-CAPACITORS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061400

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34450

Uniform Freight Classification (UFC_CD_MODF_3040)

CONDENSERS-PARTS-NOI-CAPACITORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-00-938-4649 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSJU1ZEA0
DNSMSJU1EA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5910-00-938-4649 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000000DOZZQQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-00-938-4649 Submit RFQ
MRCDecoded RequirementClear Text Reply
AECQElectrical PolarizationPOLARIZED
AECEAnode TypeSOLID
ADAUBody Height0.170 INCHES NOMINAL
ADAQBody Length0.285 INCHES NOMINAL
ADATBody Width0.225 INCHES NOMINAL
AAQLBody StyleW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CWNJCapacitive Electrode MaterialTANTALUM
CQBQCapacitance Value Per Section15.000 MICROFARADS SINGLE SECTION
CWJKCase MaterialPLASTIC
AEBPCenter To Center Distance Between Terminals Parallel To Length0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM
CWQHDc Leakage At Reference Temp0.500 MICROAMPERES
CWPMDissipation Factor At Reference Temp In Percent6.0000
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
CQWMNonderated Continuous Voltage Rating And Type Per Section10.0 DC SINGLE SECTION
AARGReliability IndicatorNOT ESTABLISHED
AEBZSchematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
CRTPTolerance Range Per Section-10.00/+10.00 PERCENT SINGLE SECTION
ABJTTerminal Length1.500 INCHES NOMINAL
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
CWSGTerminal Surface TreatmentSOLDER


Back to Top