Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
TC10-124 | 3 - Design Control Reference | 2 - Production Item | PIEZOTHERMX CORPORATION | 50056 | ![]() |
913-4487-270 | 7 - Vendor Item Drawing Reference | 2 - Production Item | ROCKWELL COLLINS, INC. | 13499 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 009669622 | A010B0 | 00007 | X | 1 | A | P | U | 28 Sep 1966 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB | ||||||||||||||||||||||||||||||
ZG | ||||||||||||||||||||||||||||||
ZU | ||||||||||||||||||||||||||||||
ZW | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
A918 | 5 | L | Z | CD | 1 Jun 2006 | |||||||||||||||||||||||||
FXGX | 5 | L | Z | SX | 1 Jun 2006 | |||||||||||||||||||||||||
MC49 | 5 | L | Z | PA | 1 Jun 2006 | |||||||||||||||||||||||||
N9BN | 5 | L | Z | GH | KE | 1 Jun 2006 | ||||||||||||||||||||||||
ZU01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
ZG01 | 1 Oct 2009 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 3 | TX | D | TC10-124 | 50056 | ![]() | ||||
3 | 7 | 2 | 1 | TX | D | 913-4487-270 | 13499 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | J | U | 1 | Z | EA | 0 | |
DF | SMS | J | U | 1 | N | EA | 0 | |
DM | SMS | J | U | 1 | Z | EA | 0 | |
DN | SMS | J | U | 1 | EA | 0 | ||
DS | SMS | J | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.200 INCHES NOMINAL |
ADAQ | Body Length | 0.200 INCHES NOMINAL |
ADAT | Body Width | 0.100 INCHES NOMINAL |
AAQL | Body Style | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
CQBQ | Capacitance Value Per Section | 10.000 PICOFARADS SINGLE SECTION |
CWJK | Case Material | PLASTIC |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 500.0 DC SINGLE SECTION |
CQLZ | Temp Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius | 1000.0 SINGLE SECTION |
CWPK | Insulation Resistance At Reference Temp | 100000.0 MEGOHMS |
CWQF | Quality Factor At Reference Temp | 300.0000 |
AARG | Reliability Indicator | NOT ESTABLISHED |
AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
CRHD | Tolerance Of Temp Coefficient Per Section In Ppm Per Deg Celsius | -15.0/+15.0 SINGLE SECTION |
CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |
ABJT | Terminal Length | 1.250 INCHES MINIMUM |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |