| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 0N230645 | 3 - Design Control Reference | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5910 | 010350375 | A010B0 | 00006 | X | K | A | P | A | 0 | 3 Feb 1977 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S018 | 0 | 0 | B | 1 Apr 1991 | ||||||||||||||||||||||||||
Not Established
INVENTORY CONTROL POINT (ICP)-REGULATED (Service/Agency use only.) Issue, transfer, or shipment is controlled by the ICP. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedure.
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 2 | 2 | XP | D | 0N230645 | 98230 | | ||||
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
National Security Agency, Fort George G. Meade, MD 20755-6000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 0 | XP | 0 | 3 Feb 1977 |
Items under the specification control of Defense Threat Reduction Agency (DTRA) or National Security Agency (NSA).
National Security Agency, Fort George G. Meade, MD 20755-6000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XP |
National Security Agency, Fort George G. Meade, MD 20755-6000
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAU | Body Height | 1.062 INCHES NOMINAL |
| ADAQ | Body Length | 3.250 INCHES NOMINAL |
| AAQL | Body Style | W/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE |
| ADAT | Body Width | 1.000 INCHES NOMINAL |
| CQBQ | Capacitance Value Per Section | 75.000 MICROFARADS SINGLE SECTION |
| CWJK | Case Material | PLASTIC |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.500 INCHES NOMINAL |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.500 INCHES NOMINAL |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 3.625 INCHES NOMINAL |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.625 INCHES NOMINAL |
| CWPM | Dissipation Factor At Reference Temp In Percent | 0.2500 |
| CBBL | Features Provided | HERMETICALLY SEALED CASE |
| AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED MOUNTING HOLES |
| CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 50.0 DC SINGLE SECTION |
| CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM |
| CWPK | Insulation Resistance At Reference Temp | 1200.0 MEGOHMS |
| CWPN | Power Factor At Reference Temp In Percent | 2.0000 |
| AARH | Reliability Failure Rate Level In Percent | 0.0001 |
| AARG | Reliability Indicator | ESTABLISHED |
| AEBZ | Schematic Diagram Designator | ELECTRODE(S) GROUNDED TO CASE |
| CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |
| AEBV | Unthreaded Mounting Hole Diameter | 0.169 INCHES NOMINAL |
| ABJT | Terminal Length | 0.343 INCHES NOMINAL |
| TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG |
| TEST | Test Data Document | 98230-0N230645 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |