| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 7C023103X0500D | 3 - Design Control Reference | 2 - Production Item | SPRAGUE ELECTRIC CO | 56289 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5910 | 011076104 | A010B0 | 00007 | X | 1 | A | P | U | 10 Feb 1981 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YK01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 2 | 4 | 9Z | D | 7 | 7C023103X0500D | 56289 | | |||
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number represents an obsolete or discontinued item which has rolled back into stock, and it would not be appropriate to mix stock with the current item. (Justification Code 7 shall be used only when it is necessary to acquire an NSN for a cancelled, superseded, or obsolete reference number which matches a reference number in the FLIS data base coded RNCC 5 and RNVC 9.)
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 6 | 10 Feb 1981 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YK | P | 658 | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Kuwait
77.5
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAU | Body Height | 0.160 INCHES NOMINAL |
| ADAQ | Body Length | 0.390 INCHES NOMINAL |
| ADAT | Body Width | 0.275 INCHES NOMINAL |
| AAQL | Body Style | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| CQBQ | Capacitance Value Per Section | 0.010 MICROFARADS SINGLE SECTION |
| CWJK | Case Material | PLASTIC |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.250 INCHES NOMINAL |
| CWPM | Dissipation Factor At Reference Temp In Percent | 4.0000 |
| CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 500.0 DC SINGLE SECTION |
| CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CWPK | Insulation Resistance At Reference Temp | 5000.0 MEGOHMS |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
| CRTP | Tolerance Range Per Section | -20.00/+20.00 PERCENT SINGLE SECTION |
| CQFB | Voltage Temp Limits Per Section In Percent Capacitance Change | -56.0/+22.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
| AEBT | Terminal Diameter | 0.020 INCHES NOMINAL |
| ABJT | Terminal Length | 1.250 INCHES MINIMUM |
| TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |