5910-01-189-5477

CAPACITOR,FIXED,ELECTROLYTIC


5910-01-189-5477 (5910011895477, 011895477)
Part Numbers (2 listings): 0N303497-1 | 601D687G050GL4 |
Summary

FSG 59 / FSC 5910

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 17 Sep 1984

Unit Weight: 0.9 lbs

Unit Size: 5.8in x 3.5in x 3.5in

Unit Pack Cube: 0.041 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5910-01-189-5477 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0N303497-13 - Design Control Reference2 - Production ItemNATIONAL SECURITY AGENCY  98230    CAGE 98230  
601D687G050GL45 - Replaced / Discontinued2 - Production ItemSPRAGUE ELECTRIC CO  56289      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5910-01-189-5477 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595910011895477A010B000008X1APA017 Sep 1984
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5910

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Capacitors

011895477

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5910-01-189-5477

A010B0

Federal Item Identification Guide (FIIG_4065)

00008

Item Naming Code (INC_4080)

17 Sep 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5910-01-189-5477 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZA011 Apr 1991
FJ5NF6011CF1 Nov 1996
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

F

Item Management Code (IMC_2744)


Single Agency: Items assigned to a single agency other than the commodity oriented integrated manager for integrated management or control. (These include items controlled by the Energy Research and Development Administration or National Security Agency, or items assigned to the Army Tank-Automotive Command (TACOM) for integrated management.)


FLIS - SEG C - REFERENCE NUMBER | NSN 5910-01-189-5477 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321CM0N303497-1  98230   CAGE/98230
52ETX601D687G050GL4  56289  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

CM

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army CECOM Communications, Fort Huachuca, AZ 85613-7431

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5910-01-189-5477 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
0XP017 Sep 1984
Code Definitions

0

Item Standardization Code (ISC_2650)


Items under the specification control of Defense Threat Reduction Agency (DTRA) or National Security Agency (NSA).

XP

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


National Security Agency, Fort George G. Meade, MD 20755-6000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Sep 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5910-01-189-5477 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CM
Code Definitions

CM

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army CECOM Communications, Fort Huachuca, AZ 85613-7431

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5910-01-189-5477 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFPDDU1NEA0
DFFPDDU1EA0
Code Definitions

FPD

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Air Force Cryptologic Support Group, 230 Hall Blvd, Bldg 2028, San Antonio, TX 78243-7081

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG W - PACKAGING DATA | NSN 5910-01-189-5477 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APB0.9 lbs5.8in x 3.5in x 3.5in0.041 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZ
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

B

Item Type Storage Code (ITM_TYP_STOR_5156)


Unheated General Purpose

0.9 lbs

Unit Pack Weight (UP_WT_5153)

5.8in x 3.5in x 3.5in

Unit Pack Size (UP_SZ_5154)

0.041 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Intermediate Container Code (INTMD_CTNR_CD_5167)


Special requirement – See specific instructions or drawings provided.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5910-01-189-5477 Submit RFQ
MRCDecoded RequirementClear Text Reply
AECQElectrical PolarizationPOLARIZED
ABPMBody Diameter0.812 INCHES MAXIMUM
ADAQBody Length2.188 INCHES MINIMUM AND 2.312 INCHES MAXIMUM
AAQLBody StyleW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS
CQBQCapacitance Value Per Section680.000 MICROFARADS SINGLE SECTION
CWNJCapacitive Electrode MaterialALUMINUM
CWSZCase Insulation MaterialPLASTIC
CWJKCase MaterialMETAL
CQLHDc Leakage At Maximum Operating Temp540.0 MICROAMPERES
CWQHDc Leakage At Reference Temp90.000 MICROAMPERES
CWQCEquivalent Series Resistance At Reference Temp In Ohms0.20
CQWMNonderated Continuous Voltage Rating And Type Per Section50.0 DC SINGLE SECTION
CQJJNonderated Operating Temp-55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM
AECNImpedance At Minimum Operating Temp In Ohms3.9
AARHReliability Failure Rate Level In Percent1.0001.0001.000
AARGReliability IndicatorESTABLISHEDESTABLISHEDESTABLISHED
AEBZSchematic Diagram DesignatorELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
CRTPTolerance Range Per Section-10.00/+75.00 PERCENT SINGLE SECTION
AEBTTerminal Diameter0.040 INCHES NOMINAL
ABJTTerminal Length2.250 INCHES NOMINAL2.250 INCHES NOMINAL2.250 INCHES NOMINAL
CWSGTerminal Surface TreatmentSOLDER
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD


Back to Top