Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
M39003/01-8053 | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | |
MIL-PRF-39003/1 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
MIL-C-39003/1 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | |
826012-6053 | 5 - Replaced / Discontinued | 9 - No Longer Used | THALES DEFENSE & SECURITY, INC. | 65597 | |
402-9-98090-030 | 5 - Replaced / Discontinued | 9 - No Longer Used | BRITISH AEROSPACE LAND & SEA | K1423 | |
10138685 | 6 - Informative Reference | 9 - No Longer Used | PAEAEESIKUNTA | A486G | |
P430007229 | C - Advisory Reference | 1 - Incomplete Part Number | F E L CORP | 16786 | |
MS9003/01-2271 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003-01-2991 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003/01-7053 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003/01-7054 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003-1-2031 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003-1-2511 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003/01-2271 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003/01-2291 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
M39003/1-2512 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
441-0925-019 | C - Advisory Reference | 1 - Incomplete Part Number | BOEING COMPANY, THE | 94756 | |
CS13D226K | C - Advisory Reference | 1 - Incomplete Part Number | MALLORY SONALERT PRODUCTS INC. | 90201 | |
102-303-226 | C - Advisory Reference | 1 - Incomplete Part Number | L-3 COMMUNICATIONS CORPORATION | 20747 | |
7906956-21 | C - Advisory Reference | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 90536 | |
CSR13D226KP | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
CSR13D226M | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
CSR13D226ML | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
JM39003/1-2271 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
184-9089-320 | C - Advisory Reference | 1 - Incomplete Part Number | ROCKWELL COLLINS, INC. | 13499 | |
M472069 | C - Advisory Reference | 1 - Incomplete Part Number | QUALIMETRICS INC | 50655 | |
CSR13D226K | C - Advisory Reference | 1 - Incomplete Part Number | ARNOUX CORP | 26310 | |
2604271-3 | C - Advisory Reference | 1 - Incomplete Part Number | ALLIANT TECHSYSTEMS OPERATIONS LLC | 06424 | |
803453 | C - Advisory Reference | 1 - Incomplete Part Number | NAI TECHNOLOGIES INC | 07342 | |
882455 | C - Advisory Reference | 1 - Incomplete Part Number | NAI TECHNOLOGIES INC | 07342 | |
MS-39003/01-2271 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY STANDARDS | 96906 | |
187720-005 | C - Advisory Reference | 1 - Incomplete Part Number | TYMSHARE INC | 56200 | |
TS2-010-226-20 | C - Advisory Reference | 1 - Incomplete Part Number | AVX TANTALUM CORPORATION | 17554 | |
D180-0228 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | |
1508-182816 | C - Advisory Reference | 1 - Incomplete Part Number | FLUKE CORPORATION | 89536 | |
CB4011-00 | C - Advisory Reference | 1 - Incomplete Part Number | THOMSON INC | 32760 | |
T320B226M010AS | C - Advisory Reference | 1 - Incomplete Part Number | KEMET ELECTRONICS CORPORATION | 31433 | |
C0693 | C - Advisory Reference | 1 - Incomplete Part Number | BEI SENSORS & SYSTEMS COMPANY, INC. | 06811 | |
TCT226K2SD | C - Advisory Reference | 1 - Incomplete Part Number | TELEPHONE SYSTEMS/COMMUNICATIONS | 10241 | |
CS13BD226K | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | |
150D 22MFD ELECT | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | |
150D226X9010B | C - Advisory Reference | 1 - Incomplete Part Number | SPRAGUE ELECTRIC CO | 56289 | |
T310C226K010AS | C - Advisory Reference | 1 - Incomplete Part Number | UNION CARBIDE CORP MATERIALS SYSTEMS | 05397 | |
TAG00-2-2/25-50/20 | C - Advisory Reference | 1 - Incomplete Part Number | ITT SEMICONDUCTORS | 15238 | |
150D226X9015B2 | C - Advisory Reference | 1 - Incomplete Part Number | JOANELL LABORATORIES INC | 04200 | |
0180-1025 | E - Replace Reference Number | 8 - Replacement NSN | AGILENT TECHNOLOGIES, INC. | 1LQK8 | |
260D007 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | |
150D226X9015B3 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | |
150D226X0015B3 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | |
140081 | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | |
STA07A | E - Replace Reference Number | 8 - Replacement NSN | SPRAGUE ELECTRIC CO | 56289 | |
24504371 | E - Replace Reference Number | 8 - Replacement NSN | MAGNETIC PERIPHERALS INC | 19333 | |
402-9-98090-030 | E - Replace Reference Number | 8 - Replacement NSN | SELEX ES LTD | K0668 | |
10526650 | E - Replace Reference Number | 8 - Replacement NSN | US ARMY ARDEC RDECOM | 19200 | |
217C9-5 | E - Replace Reference Number | 8 - Replacement NSN | BOEING COMPANY, THE | 94756 | |
441-0331-007 | E - Replace Reference Number | 8 - Replacement NSN | BOEING COMPANY, THE | 94756 | |
0180-1025 | E - Replace Reference Number | 8 - Replacement NSN | HEWLETT PACKARD CO | 28480 | |
24504371 | E - Replace Reference Number | 8 - Replacement NSN | MAGNETIC PERIPHERALS INC | 52849 | |
441-0331-007 | E - Replace Reference Number | 8 - Replacement NSN | ROCKWELL INTERNATIONAL CORP | 89372 | |
WCS14D226M | E - Replace Reference Number | 8 - Replacement NSN | GENERAL INSTRUMENT CORP | 72699 | |
140081 | E - Replace Reference Number | 8 - Replacement NSN | ANN ARBOR TERMINALS INC | 54236 | |
24504371 | E - Replace Reference Number | 8 - Replacement NSN | SYNTEGRA / USA/ INC | 59661 | |
92427089 | E - Replace Reference Number | 8 - Replacement NSN | CERIDIAN CORP | 52810 | |
4K107 | E - Replace Reference Number | 8 - Replacement NSN | BC COMPONENTS | 56699 |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5910 | 012449442 | A010B0 | 00008 | Y | 1 | A | P | A | 21 Nov 1986 |
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1996 | |||||||||||||||||||||||||||||
ZA01 | 1 May 1996 | |||||||||||||||||||||||||||||
YB01 | 1 May 1997 | |||||||||||||||||||||||||||||
ZE01 | 1 Sep 1998 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
ZH01 | 1 Mar 1999 | |||||||||||||||||||||||||||||
ZG01 | 1 Jun 2000 | |||||||||||||||||||||||||||||
ZX01 | 1 Apr 2001 | |||||||||||||||||||||||||||||
ZC01 | 1 Jun 2001 | |||||||||||||||||||||||||||||
YA01 | 1 Jul 2001 | |||||||||||||||||||||||||||||
ZN01 | 1 Jun 2003 | |||||||||||||||||||||||||||||
WP01 | 1 Aug 2004 | |||||||||||||||||||||||||||||
ZU01 | 1 May 2006 | |||||||||||||||||||||||||||||
A918 | A196 | 1 | T | Z | CL | AZ | CT | CL | BF | BD | 1 Aug 2006 | |||||||||||||||||||
BGX1 | BTX1 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
C911 | C007 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
DGXT | DTX2 | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
FXGX | FXTX | 1 | T | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
G86X | G86E | 1 | T | 1 Aug 2006 | ||||||||||||||||||||||||||
MC49 | MC13 | 1 | T | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | T | Z | KE | GT | KE | JS | JB | HX | HS | HD | JV | 1 Aug 2006 | ||||||||||||||||
S911 | S007 | 1 | T | Z | XN | 1 Aug 2006 | ||||||||||||||||||||||||
ZR01 | 1 Dec 2007 | |||||||||||||||||||||||||||||
WF01 | 1 May 2011 | |||||||||||||||||||||||||||||
ZT01 | 1 Nov 2011 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval ICP, Philadelphia, PA 19111
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Naval ICP, Philadelphia, PA 19111
Naval ICP, Mechanicsburg, PA 17055-0788
Navy ICP, Mechanicsburg, PA 17055-0788
HD
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 2 | E | TX | M39003/01-8053 | 81349 | |||||||
4 | 1 | E | ZZ | MIL-PRF-39003/1 | 81349 | |||||||
5 | 9 | E | TX | B | MIL-C-39003/1 | 81349 | ||||||
3 | 5 | 9 | 5 | KE | D | 402-9-98090-030 | K1423 | |||||
5 | 9 | 5 | 48 | B | 826012-6053 | 65597 | ||||||
4 | 6 | 9 | 9 | WF | B | 10138685 | A486G | |||||
C | 1 | 6 | ZZ | AC | MS9003/01-2271 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | 441-0925-019 | 94756 | ||||||
C | 1 | 6 | ZZ | AC | MS-39003/01-2271 | 96906 | ||||||
C | 1 | 6 | ZZ | AC | M39003/1-2512 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | 1508-182816 | 89536 | ||||||
C | 1 | 6 | ZZ | AC | CS13D226K | 90201 | ||||||
C | 1 | 6 | ZZ | AC | 7906956-21 | 90536 | ||||||
C | 1 | 6 | ZZ | AC | 150D226X9015B2 | 04200 | ||||||
C | 1 | 6 | ZZ | AC | T310C226K010AS | 05397 | ||||||
C | 1 | 6 | ZZ | AC | 2604271-3 | 06424 | ||||||
C | 1 | 6 | ZZ | AC | C0693 | 06811 | ||||||
C | 1 | 6 | ZZ | AC | 803453 | 07342 | ||||||
C | 1 | 6 | ZZ | AC | 882455 | 07342 | ||||||
C | 1 | 6 | ZZ | AC | TCT226K2SD | 10241 | ||||||
C | 1 | 6 | ZZ | AC | 184-9089-320 | 13499 | ||||||
C | 1 | 6 | ZZ | AC | TAG00-2-2/25-50/20 | 15238 | ||||||
C | 1 | 6 | ZZ | AC | P430007229 | 16786 | ||||||
C | 1 | 6 | ZZ | AC | TS2-010-226-20 | 17554 | ||||||
C | 1 | 6 | ZZ | AC | D180-0228 | 28480 | ||||||
C | 1 | 6 | ZZ | AC | T320B226M010AS | 31433 | ||||||
C | 1 | 6 | ZZ | AC | CB4011-00 | 32760 | ||||||
C | 1 | 6 | ZZ | AC | M472069 | 50655 | ||||||
C | 1 | 6 | ZZ | AC | 102-303-226 | 20747 | ||||||
C | 1 | 6 | ZZ | AC | CSR13D226K | 26310 | ||||||
C | 1 | 6 | ZZ | AC | 187720-005 | 56200 | ||||||
C | 1 | 6 | ZZ | AC | 150D 22MFD ELECT | 56289 | ||||||
C | 1 | 6 | ZZ | AC | 150D226X9010B | 56289 | ||||||
C | 1 | 6 | ZZ | AC | CS13BD226K | 56289 | ||||||
C | 1 | 6 | ZZ | AC | CSR13D226KP | 81349 | ||||||
C | 1 | 6 | ZZ | AC | CSR13D226M | 81349 | ||||||
C | 1 | 6 | ZZ | AC | CSR13D226ML | 81349 | ||||||
C | 1 | 6 | ZZ | AC | JM39003/1-2271 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | M39003-01-2991 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | M39003-1-2031 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | M39003-1-2511 | 81349 | ||||||
C | 1 | E | ZZ | 5 | AB | M39003/01-2271 | 81349 | |||||
C | 1 | 6 | ZZ | AC | M39003/01-2291 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | M39003/01-7053 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | M39003/01-7054 | 81349 | ||||||
E | 8 | 5 | TX | STA07A | 56289 | |||||||
E | 8 | 5 | TX | 4K107 | 56699 | |||||||
E | 8 | 5 | TX | 24504371 | 59661 | |||||||
3 | E | 8 | 3 | ZZ | D | 150D226X9015B3 | 56289 | |||||
E | 8 | 5 | TX | 260D007 | 56289 | |||||||
3 | E | 8 | 3 | ZZ | D | 150D226X0015B3 | 56289 | |||||
4 | E | 8 | 5 | TX | D | 140081 | 56289 | |||||
3 | E | 8 | 5 | ZZ | B | 0180-1025 | 28480 | |||||
4 | E | 8 | 1 | TX | D | 92427089 | 52810 | |||||
4 | E | 8 | 5 | TX | D | 24504371 | 52849 | |||||
4 | E | 8 | 5 | TX | D | 140081 | 54236 | |||||
E | 8 | 1 | BF | 10526650 | 19200 | |||||||
4 | E | 8 | 5 | TX | B | 24504371 | 19333 | |||||
E | 8 | 5 | ZZ | 0180-1025 | 1LQK8 | |||||||
3 | E | 8 | 1 | ZZ | D | 217C9-5 | 94756 | |||||
3 | E | 8 | 1 | HD | D | 441-0331-007 | 94756 | |||||
E | 8 | 5 | TX | WCS14D226M | 72699 | |||||||
E | 8 | 5 | TX | 441-0331-007 | 89372 | |||||||
E | 8 | 5 | KE | D | 402-9-98090-030 | K0668 |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Naval ICP, Philadelphia, PA 19111
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Federal Aviation Administration, Oklahoma City, OK 73125
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)
The reference number is of the type for which an indication of document availability is not required.
Finland
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Navy
Match of reference number(s) by an associated code is not valid for this reference.
Air Force
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
B | TX | 0 | E | TX | 0 | 3 Jun 1992 | 5910000073974 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Oct 1969 | 5910000430874 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 5 Oct 1980 | 5910001584750 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 3 Nov 1973 | 5910001650629 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 26 Jul 1986 | 5910001652830 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Feb 1981 | 5910004564454 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Nov 1971 | 5910004600851 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 11 Oct 1972 | 5910004900239 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 3 Nov 1973 | 5910005427409 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 16 Dec 1977 | 5910005492489 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Mar 1968 | 5910006605006 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 7 Jan 1979 | 5910007199907 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 0 | 24 Feb 1965 | 5910007524270 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Nov 1971 | 5910007524289 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910007524476 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 15 Mar 1983 | 5910007771095 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 29 Jan 1966 | 5910007791224 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 28 Jul 1967 | 5910007839403 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910007928165 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 0 | 7 May 1982 | 5910008077253 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Feb 1965 | 5910008120940 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910008159714 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 19 Jun 1966 | 5910008213271 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 13 Nov 1969 | 5910008247740 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Nov 1971 | 5910008402999 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 15 Mar 1983 | 5910008500830 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 8 Oct 1975 | 5910008551191 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 24 Nov 1971 | 5910008792903 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 19 Jun 1966 | 5910008838518 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 19 Jun 1966 | 5910008927910 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 10 Jan 1972 | 5910009110689 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910009140831 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 10 Nov 1971 | 5910009146506 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 17 Nov 1971 | 5910009256867 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 26 Jun 1982 | 5910009310611 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 28 Jul 1967 | 5910009494827 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 17 Jan 1968 | 5910009666599 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910009892584 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 20 Dec 1969 | 5910009893637 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 17 Dec 1972 | 5910009896809 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 19 Jun 1966 | 5910009939991 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 10 Oct 1971 | 5910009960532 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 3 Nov 1973 | 5910009960667 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 3 Nov 1973 | 5910009974079 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 13 Sep 1989 | 5910010360889 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 16 Nov 1979 | 5910010781570 | 22 Sep 1992 |
B | TX | 0 | 3 | TX | 1 | 8 Feb 1986 | 5910011345111 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 22 Sep 1992 | 5910012041032 | 22 Sep 1992 |
B | TX | 0 | E | TX | 1 | 1 Apr 1988 | 5910012460455 | 22 Sep 1992 |
B | TX | 0 | E | 9T | 1 | 3 Jun 1992 | 5910012585773 | 22 Sep 1992 |
A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item no longer authorized for procurement which has been replaced by an item contained in a new or revised superseding specification or standard.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
DLIS, Battle Creek, MI 49037-3084
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TH | 72D | Z | 9 | A | H | Z | P | 061400 | X | 34450 | CONDENSERS-PARTS-NOI-CAPACITORS |
Defense Supply Center Columbus, Columbus, OH 43215
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 1 | Z | EA | 0 | |
DF | SMS | D | U | 1 | N | EA | 0 | |
DM | SMS | D | U | 1 | Z | EA | 0 | |
DN | SMS | D | U | 1 | EA | 0 | ||
DS | SMS | D | U | 1 | N | EA | 0 | |
GP | SMS | D | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA | 0.1 lbs | 0.003 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | 00 | 0 | D3 | ZZ | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
No requirement
Not Applicable
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AECQ | Electrical Polarization | POLARIZED |
AECE | Anode Type | SOLID |
ABPM | Body Diameter | 0.170 INCHES MINIMUM AND 0.201 INCHES MAXIMUM |
ADAQ | Body Length | 0.474 INCHES NOMINAL |
AAQL | Body Style | W/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS |
CWNJ | Capacitive Electrode Material | TANTALUM |
CQBQ | Capacitance Value Per Section | 22.000 MICROFARADS SINGLE SECTION |
CWSZ | Case Insulation Material | PLASTIC |
CWJK | Case Material | METAL |
CRTL | Criticality Code Justification | FEAT |
CQLH | Dc Leakage At Maximum Operating Temp | 40.0 MICROAMPERES |
CWQH | Dc Leakage At Reference Temp | 2.000 MICROAMPERES |
CWPM | Dissipation Factor At Reference Temp In Percent | 6.000 |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
AARF | Mil-Std-1276 Wire Lead Type Designator | N-4N-4N-4 |
CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 15.0 DC SINGLE SECTION |
CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
AARH | Reliability Failure Rate Level In Percent | 0.0010.0010.001 |
AARG | Reliability Indicator | ESTABLISHEDESTABLISHEDESTABLISHED |
AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
FEAT | Special Features | WEIBULL GRADED FAILURE RATE |
CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |
ZZZK | Specification/Standard Data | 81349-MIL-PRF-39003/1 GOVERNMENT SPECIFICATION |
AEBT | Terminal Diameter | 0.020 INCHES NOMINAL |
ABJT | Terminal Length | 1.500 INCHES MINIMUM1.500 INCHES MINIMUM1.500 INCHES MINIMUM |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |
TEST | Test Data Document | 81349-MIL-PRF-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |