| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 100-050-W5R-332K | 3 - Design Control Reference | 2 - Production Item | CENTRE CAPACITOR INC | 51642 | |
| 258329-21008 | 7 - Vendor Item Drawing Reference | 2 - Production Item | RAYTHEON COMPANY | 37695 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5910 | 013183674 | A010B0 | 00007 | X | K | A | P | A | 0 | 17 Apr 1990 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YQ01 | 1 Jan 2015 | |||||||||||||||||||||||||||||
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 6 | 17 Apr 1990 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TA |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AGAV | End Item Identification | MFX 711-1 |
| ADAU | Body Height | 0.100 INCHES MAXIMUM |
| ADAQ | Body Length | 0.130 INCHES MAXIMUM |
| ADAT | Body Width | 0.100 INCHES MAXIMUM |
| AAQL | Body Style | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
| CQBQ | Capacitance Value Per Section | 3300.000 PICOFARADS SINGLE SECTION |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.100 INCHES NOMINAL |
| CWPM | Dissipation Factor At Reference Temp In Percent | 2.500 |
| CQWM | Nonderated Continuous Voltage Rating And Type Per Section | 50.0 DC SINGLE SECTION |
| CQJJ | Nonderated Operating Temp | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| CWPK | Insulation Resistance At Reference Temp | 100000.0 MEGOHMS |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| AEBZ | Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
| BWGP | Section Quantity | 1 |
| CRTP | Tolerance Range Per Section | -10.00/+10.00 PERCENT SINGLE SECTION |
| CQFB | Voltage Temp Limits Per Section In Percent Capacitance Change | -15.0/+15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
| AEBT | Terminal Diameter | 0.016 INCHES NOMINAL |
| ABJT | Terminal Length | 0.560 INCHES MAXIMUM |
| CWSG | Terminal Surface Treatment | SOLDER |
| TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |