Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
865089-10 | 3 - Design Control Reference | 9 - No Longer Used | LITTON SYSTEMS INC. DIV NAVIGATION | 13973 | ![]() |
GF55922 | 5 - Replaced / Discontinued | 9 - No Longer Used | SPECTRUM CONTROL INC. | 13050 | ![]() |
865089-10 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
865089-10 | C - Advisory Reference | 1 - Incomplete Part Number | NORTHROP GRUMMAN GUIDANCE AND | 06481 | ![]() |
GF55922 | C - Advisory Reference | 1 - Incomplete Part Number | GENISCO FILTER CORP. | 07294 | ![]() |
GF55922 | C - Advisory Reference | 1 - Incomplete Part Number | GENISCO FILTER CORP. | 07294 | ![]() |
GF55922 | C - Advisory Reference | 1 - Incomplete Part Number | GENISCO FILTER CORP. | 07294 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 000092475 | A047B0 | 00765 | X | 1 | D | P | U | 29 Jul 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 3 | C | Z | KE | KE | 1 Jun 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 1 | KE | D | 865089-10 | 13973 | ![]() | ||||
5 | 9 | 5 | TX | B | GF55922 | 13050 | ![]() | |||||
C | 1 | 5 | ZZ | 9F | 865089-10 | 06481 | ![]() | |||||
C | 1 | 5 | ZZ | 9X | GF55922 | 07294 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
USA
CAGE Status Change
GIRDER
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | 72D | Z | 9 | A | H | Z | P | 061990 | X | 58500 | ELECTRICAL-EQUIP-FILTERS |
Naval ICP, Philadelphia, PA 19111
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 1.6 lbs | 0.572 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 3.000 INCHES MAXIMUM |
ADAQ | Body Length | 8.500 INCHES NOMINAL |
ADAT | Body Width | 6.000 INCHES NOMINAL |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 12.875 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 5.562 INCHES NOMINAL |
AHBX | Distance Between Mounting Surface And Lower End | 3.500 INCHES NOMINAL |
CQDW | Functional Terminal Type And Quantity | 1 CONNECTOR, RECEPTACLE OUTPUT AND 4 TURRET INPUT AND 2 TURRET GROUND |
AHBE | Maximum Voltage Drop Per Function | 140.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | Maximum Voltage Drop Per Function | 575.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | Maximum Voltage Drop Per Function | 575.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
AHBE | Maximum Voltage Drop Per Function | 575.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AHBC | Operating Current Rating Per Function In Amps | 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | Operating Current Rating Per Function In Amps | 10.0 2ND RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | Operating Current Rating Per Function In Amps | 10.0 4TH RADIO INTERFERENCE |
CQGC | Operating Voltage Rating And Type Per Function | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AFGA | Operating Temp Range | -55.0 TO 85.0 DEG CELSIUS |
CRDC | Maximum Dielectric Withstanding Dc Voltage | 500.0 VOLTS AT SEA LEVEL |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AECR | Vibration Resistance Range In Hertz | +10.0 TO 500.0 |
AKNA | Inclosure Type | HERMETICALLY SEALED |
AHAS | Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | Load Impedance Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 1ST RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 3RD RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 4TH RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
ABKW | Overall Height | 4.250 INCHES NOMINAL |
ABHP | Overall Length | 13.380 INCHES NOMINAL |
AEBV | Unthreaded Mounting Hole Diameter | 0.196 INCHES NOMINAL |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |