5915-00-012-8599

FILTER,RADIO FREQUENCY INTERFERENCE


5915-00-012-8599 (5915000128599, 000128599)
Part Numbers (3 listings): RF00752 | RF752 | 401-6987153ITEM76 |
Summary

FSG 59 / FSC 5915

DEMIL: D

DEMIL INT: 1

HMIC: P

Date Created: 18 Apr 1967

Unit Weight: 0.4 lbs

Unit Size: None

Unit Pack Cube: 0.017 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-00-012-8599 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
RF007523 - Design Control Reference2 - Production ItemEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
RF007525 - Replaced / Discontinued2 - Production ItemELECTRIC BOAT CORPORATION  96169    CAGE 96169  
RF7525 - Replaced / Discontinued9 - No Longer UsedELECTRIC BOAT CORPORATION  96169    CAGE 96169  
RF7525 - Replaced / Discontinued9 - No Longer UsedEMS DEVELOPMENT CORPORATION  13619    CAGE 13619  
401-6987153 ITEM 76D - Drawing Number Reference9 - No Longer UsedNAVAL SEA SYSTEMS COMMAND  53711    CAGE 53711  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5915-00-012-8599 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915000128599A047B000765X1DPU18 Apr 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

000128599

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-00-012-8599

A047B0

Federal Item Identification Guide (FIIG_4065)

00765

Item Naming Code (INC_4080)

18 Apr 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5915-00-012-8599 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Nov 1998
N9BNN9ND3LZGHHD1 Jun 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

L

Acquisition Method Suffix Code (AMSC_2876)


The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5915-00-012-8599 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZRF00752  13619   CAGE/13619
523ZZRF00752  96169   CAGE/96169
595ZZBRF752  96169   CAGE/96169
3595HDDRF752  13619   CAGE/13619
D95ZZ401-6987153 ITEM 76  53711   CAGE/53711
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-00-012-8599 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX07 May 1994
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

7 May 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-00-012-8599 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72DZ9AHZP061990X58500ELECTRICAL-EQUIP-FILTERS
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061990

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

58500

Uniform Freight Classification (UFC_CD_MODF_3040)

ELECTRICAL-EQUIP-FILTERS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-00-012-8599 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSJ71EA0
DSSMSJ71EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5915-00-012-8599 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.4 lbs0.017 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
DABGXD1DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.4 lbs

Unit Pack Weight (UP_WT_5153)

0.017 cu ft

Unit Pack Cube (UP_CU_5155)

DA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-1249, paper, tissue

BG

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


A-A-1898, Grade II, water resistant cellulosic cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-00-012-8599 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length3.332 INCHES NOMINAL
ADARBody Outside Diameter1.130 INCHES NOMINAL
CQDWFunctional Terminal Type And Quantity1 TAB, SOLDER LUG INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
CQDZMaximum Dielectric Withstanding Ac Rms Voltage230.0 VOLTS AT SEA LEVEL
CRDCMaximum Dielectric Withstanding Dc Voltage800.0 VOLTS AT SEA LEVEL
AHBEMaximum Voltage Drop Per Function1.15 VOLTS AC BLANK AND 4.0 VOLTS DC BLANK
AKEJMounting Facility Screw Thread Series DesignatorUNF
AXHRMounting Facility Type And Quantity1 THREADED BUSHING
CQJXNominal Thread Size0.438 INCHES
AHBCOperating Current Rating Per Function In Amps1.0 BLANK
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQGCOperating Voltage Rating And Type Per Function115.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
AKNAInclosure TypeENCASED
AHASLoad Impedance Per Function50.0 OHMS BLANK
AHBBPower Line Frequency Rating Per Function In Hertz400.0 BLANK
AHBLPrincipal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE BLANK
AHAQSource Impedance Rating Per Function50.0 OHMS BLANK
ABHPOverall Length4.272 INCHES MAXIMUM
STYLStyle DesignatorROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES


Back to Top
Back to Top