Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
82012 | 3 - Design Control Reference | 9 - No Longer Used | AEROTRONIC CONTROLS CO | 10621 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 000433909 | A047B0 | 00765 | X | 1 | D | P | U | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 1999 | |||||||||||||||||||||||||||||
N9BN | N9ND | 0 | 0 | Z | HD | HD | 1 Jun 2006 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 7 May 1994 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | P | 061990 | X | 58500 | ELECTRICAL-EQUIP-FILTERS |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.485 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
ADAQ | Body Length | 1.485 INCHES MINIMUM AND 2.015 INCHES MAXIMUM |
CQRG | Body Material | METAL |
ADAT | Body Width | 1.485 INCHES MINIMUM AND 1.515 INCHES MAXIMUM |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.000 INCHES NOMINAL |
CQDW | Functional Terminal Type And Quantity | 2 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | Functional Terminal Type And Quantity | 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
AFSV | Average Life Rating In Hours | 250.0 |
CQDZ | Maximum Dielectric Withstanding Ac Rms Voltage | 260.0 VOLTS AT SEA LEVEL |
AXHR | Mounting Facility Type And Quantity | 2 UNTHREADED HOLE |
AHBC | Operating Current Rating Per Function In Amps | 2.0 1ST RADIO INTERFERENCE |
AHBC | Operating Current Rating Per Function In Amps | 2.0 2ND RADIO INTERFERENCE |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | Operating Voltage Rating And Type Per Function | 130.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CRDC | Maximum Dielectric Withstanding Dc Voltage | 1.12 KILOVOLTS AT SEA LEVEL |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AKNA | Inclosure Type | HERMETICALLY SEALED |
AHAS | Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 1ST RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
ABHP | Overall Length | 2.765 INCHES MINIMUM AND 2.795 INCHES MAXIMUM |
AEBV | Unthreaded Mounting Hole Diameter | 0.188 INCHES NOMINAL |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |