Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
738816-04 | 3 - Design Control Reference | 2 - Production Item | GE AVIATION SYSTEMS LLC | 35351 | |
738816-04 | 5 - Replaced / Discontinued | 9 - No Longer Used | SPECTRUM CONTROL INC. | 13050 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5915 | 000649096 | A047B0 | 00765 | X | 1 | A | P | A | 29 Jun 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
N9BN | N9ND | 0 | 0 | Z | GH | KE | 1 Jun 2006 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 738816-04 | 35351 | |||||
5 | 9 | 5 | TX | 738816-04 | 13050 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 24 Apr 1968 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | Z | 9 | A | H | Z | P | 061990 | X | 58500 | ELECTRICAL-EQUIP-FILTERS |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 42 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 1.500 INCHES NOMINAL |
ADAQ | Body Length | 4.000 INCHES NOMINAL |
CQRG | Body Material | METAL |
ADAT | Body Width | 2.000 INCHES NOMINAL |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 3.000 INCHES NOMINAL |
CQDW | Functional Terminal Type And Quantity | 2 THREADED STUD INPUT 1ST FUNCTION2 THREADED STUD OUTPUT 2ND FUNCTION |
CBBL | Features Provided | NUT AND SHOCK RESISTANT |
AHCJ | Full Load Insertion Loss Frequencies In Megahertz | 0.15 AND 1.0 AND 10.0 AND 100.0 AND 200.0 AND 400.0 |
AHCK | Full Load Minimum Insertion Loss At Specified Frequency In Decibels | 100.0 AND |
AHCK | Full Load Minimum Insertion Loss At Specified Frequency In Decibels | 100.0 AND 100.0 AND 90.0 AND 90.0 |
AHCK | Full Load Minimum Insertion Loss At Specified Frequency In Decibels | 75.0 AND |
CRDC | Maximum Dielectric Withstanding Dc Voltage | 500.0 VOLTS AT SEA LEVEL |
AHBE | Maximum Voltage Drop Per Function | 1.5 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION0.5 VOLTS DC 2ND RADIO INTERFERENCE |
AKEJ | Mounting Facility Screw Thread Series Designator | UNC |
AXHR | Mounting Facility Type And Quantity | 2 THREADED STUD |
CQJX | Nominal Thread Size | 0.164 INCHES |
AHBC | Operating Current Rating Per Function In Amps | 0.75 1ST RADIO INTERFERENCE2.0 2ND RADIO INTERFERENCE |
AFGA | Operating Temp Range | +0.0/+55.0 DEG CELSIUS |
CQGC | Operating Voltage Rating And Type Per Function | 125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION30.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHCG | Maximum Temp Rise | 20.0 DEG CELSIUS |
AECR | Vibration Resistance Range In Hertz | +5.0 TO 55.0 |
AKNA | Inclosure Type | HERMETICALLY SEALED |
AHAS | Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE |
AHBB | Power Line Frequency Rating Per Function In Hertz | 400.0 BLANK |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHAQ | Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
ABKW | Overall Height | 2.700 INCHES NOMINAL |
FEAT | Special Features | TWO FILTERED FUNCTIONS |
STYL | Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |