5915-00-079-9900

FILTER,BAND PASS-BAND SUPPRESSION


5915-00-079-9900 (5915000799900, 000799900)
Part Numbers (3 listings): PS844400005F001 | F2285 | 349A |
Summary

FSG 59 / FSC 5915

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 6 Dec 1967

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5915-00-079-9900 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PS844400005F0013 - Design Control Reference9 - No Longer UsedLOCKHEED MARTIN CORPORATION  04939    CAGE 04939  
F22855 - Replaced / Discontinued2 - Production ItemCTS REEVES FREQUENCY PRODUCTS  82567      
PS844400005F0015 - Replaced / Discontinued2 - Production ItemLOCKHEED MARTIN CORPORATION  38597    CAGE 38597  
349A5 - Replaced / Discontinued2 - Production ItemBULOVA TECHNOLOGIES L.L.C.  28726      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5915-00-079-9900 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595915000799900A047B060470X1APU6 Dec 1967
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5915

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Filters and Networks

000799900

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5915-00-079-9900

A047B0

Federal Item Identification Guide (FIIG_4065)

60470

Item Naming Code (INC_4080)

6 Dec 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5915-00-079-9900 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
ZW011 Nov 2005
N9BNN9ND00ZGHKE1 Jun 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5915-00-079-9900 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3391TXDPS844400005F001  04939   CAGE/04939
3525TXD349A  28726  
3521KEDPS844400005F001  38597   CAGE/38597
3525TXDF2285  82567  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5915-00-079-9900 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX024 Apr 1968
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Apr 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5915-00-079-9900 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE658Z9AHZP062960X35140REOSTATS-PARTS-NOI
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

062960

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35140

Uniform Freight Classification (UFC_CD_MODF_3040)

REOSTATS-PARTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5915-00-079-9900 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSZU1EA0
DSSMSZU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5915-00-079-9900 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00DABGXD1DO00QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

DA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-1249, paper, tissue

BG

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


A-A-1898, Grade II, water resistant cellulosic cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5915-00-079-9900 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFSVAverage Life Rating In Hours500.0
ADAUBody Height0.610 INCHES NOMINAL
ADAQBody Length1.170 INCHES MINIMUM
ADATBody Width0.725 INCHES MINIMUM
AEBYDistance Between Centerlines Of Mounting Facilities Parallel To Body Length0.982 INCHES NOMINAL
CRBCDiscrimination At Specified Frequencies Per Function In Decibels80.0 MINIMUM SINGLE BAND PASS AND 3.0 MAXIMUM SINGLE BAND PASS AND 80.0 MINIMUM SINGLE BAND PASS
CRBBFrequency Band Width Per Function18.276 MEGAHERTZ SINGLE BAND PASS AND 18.306 MEGAHERTZ SINGLE BAND PASS
CRBBFrequency Band Width Per Function18.276 MEGAHERTZ SINGLE BAND SUPPRESSION AND 18.306 MEGAHERTZ SINGLE BAND SUPPRESSION 2ND FUNCTION
CQDWFunctional Terminal Type And Quantity2 PIN INPUT 1ST FUNCTION
CQDWFunctional Terminal Type And Quantity2 PIN OUTPUT 2ND FUNCTION
CQRGBody MaterialMETAL
CRBCDiscrimination At Specified Frequencies Per Function In Decibels80.0 MINIMUM SINGLE BAND SUPPRESSION AND 3.0 MAXIMUM SINGLE BAND SUPPRESSION AND 3.0 MAXIMUM SINGLE BAND SUPPRESSION AND 80.0 MINIMUM SINGLE BAND SUPPRESSION 2ND FUNCTION
AXHRMounting Facility Type And Quantity4 TERMINAL
AHAVOutput Impedance Per Function W/Source Across Input600.0 OHMS SINGLE BAND SUPPRESSION
AFGAOperating Temp Range-55.0 TO 90.0 DEG CELSIUS
AHBLPrincipal Circuitry Type Per FunctionCRYSTAL SINGLE BAND PASS 1ST FUNCTION
CQFCSpecified Frequencies Of Discrimination Per Function18.082 MEGAHERTZ SINGLE BAND PASS AND 18.276 MEGAHERTZ SINGLE BAND PASS AND 18.306 MEGAHERTZ SINGLE BAND PASS AND 18.500 MEGAHERTZ SINGLE BAND PASS 1ST FUNCTION
AKNAInclosure TypeHERMETICALLY SEALED
AHAUInput Impedance Per Function W/Load600.0 OHMS SINGLE BAND PASS 1ST FUNCTION
AHAUInput Impedance Per Function W/Load600.0 OHMS SINGLE BAND SUPPRESSION
CQDRInsertion Loss At Reference Frequency Per Function In Decibels3.0 SINGLE BAND PASS
CQDRInsertion Loss At Reference Frequency Per Function In Decibels3.0 SINGLE BAND SUPPRESSION
AHBLPrincipal Circuitry Type Per FunctionCRYSTAL SINGLE BAND SUPPRESSION
AHAJReference Frequency Per Function18.291 IGNITION CUP MIXTURE ANY ACCEPTABLE
AHAJReference Frequency Per Function18.291 MEGAHERTZ SINGLE BAND PASS 1ST FUNCTION
ABKWOverall Height1.110 INCHES NOMINAL
AECRVibration Resistance Range In Hertz+10.0/+500.0
CQFCSpecified Frequencies Of Discrimination Per Function18.306 MEGAHERTZ SINGLE BAND SUPPRESSION AND 18.500 MEGAHERTZ SINGLE BAND SUPPRESSION
STYLStyle DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE


Back to Top